Data Domain: Troubleshooting a "Net Set Up Flag Failure" Error

摘要: This article discusses a "net set up flag failure when an interface is enabled.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

When an interface is enabled, the error net set up flag failure may appear:

sysadmin@dd01-p1(active:1)# net enable veth2
net set up flag failure for: eth8a
sysadmin@dd01-p1(active:1)#

sysadmin@dd01-p1(active:1)# net enable ethMa 
net set up flag failure for: ethMa
sysadmin@dd01-p1(active:1)#

原因

There can be multiple causes of this error:

  • The network card driver must be unloaded and reloaded.
  • A memory allocation issue occurs in one of the file system layers.
  • The network card may be defective.
  • Older Data Domain models using Cyber Recovery may not have enough memory installed.  

解决方案

  1. Reboot the Data Domain system. If the issue persists, continue to step 2.
  2. Drain flea power from the Data Domain system:
    1. Power the Data Domain system down gracefully.
    2. Disconnect the server from all power and network cables.
    3. Hold down the power button continuously for at least ten seconds.
    4. Insert power and network cables back into the system.
    5. Wait two minutes before powering on the server to give the iDRAC time to initialize.
    6. Power the system on.
  3. Engineering recommends that older Data Domain systems be rebooted approximately every 3 months. This helps to prevent Ethernet driver allocation failure due to memory fragmentation.
  4. If the issue persists, contact Data Domain support.

其他信息

Our engineering team is working on updates to the network card drivers and DDOS code to address the problem.

受影响的产品

Data Domain
文章属性
文章编号: 000417138
文章类型: Solution
上次修改时间: 19 1月 2026
版本:  1