Connectrix B-Series: After Upgrading to Fabric OS 9.1.1c, Inline Commands with the Use of "fosexec" Command Return an Error

摘要: After upgrading to Fabric OS (FOS) 9.1.1c, unable to run inline commands from UNIX or Linux server to the switch with the "fosexec" commands.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

Environment:

Fabric OS 9.1.1c

Issue:

The outputs show errors when running an inline command from a UNIX or Linux server. The command stops responding when probing a different logical Switch FID on the same chassis. Example:

[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.1.1c
         v9.1.1c
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

原因

This issue was found during internal testing. A change in the error was found when upgrade to FOS 9.2.0a was done.

Error:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl     Primary/Secondary Versions
------------------------------------------
FOS      v9.2.0a
         v9.2.0a
---------------------------------------------------

"firmwareshow" on FID 44:

[hosttest@VM3198 ~]$

解析度

Resolution:

Upgrade to Fabric OS 9.2.0b or later.

Workaround:

Run the commands directly on the switch.