Connectrix B-Series: After Upgrading to Fabric OS 9.1.1c, Inline Commands with the Use of "fosexec" Command Return an Error
摘要: After upgrading to Fabric OS (FOS) 9.1.1c, unable to run inline commands from UNIX or Linux server to the switch with the "fosexec" commands.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
Environment:
Fabric OS 9.1.1c
Issue:
The outputs show errors when running an inline command from a UNIX or Linux server. The command stops responding when probing a different logical Switch FID on the same chassis. Example:
[hosttest@VM1234 ~]$
[hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@aa.bb.cc.dd's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
/etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.1.1c
v9.1.1c
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$原因
This issue was found during internal testing. A change in the error was found when upgrade to FOS 9.2.0a was done.
Error:
Error:
[hosttest@VM3198 ~]$
[hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow'
hosttest@10.60.23.25's password:
/bin/stty: 'standard input': Inappropriate ioctl for device
/bin/stty: 'standard input': Inappropriate ioctl for device
Appl Primary/Secondary Versions
------------------------------------------
FOS v9.2.0a
v9.2.0a
---------------------------------------------------
"firmwareshow" on FID 44:
[hosttest@VM3198 ~]$解析度
Resolution:
Upgrade to Fabric OS 9.2.0b or later.
Workaround:
Run the commands directly on the switch.