NetWorker: Como definir o tempo de rollover/truncamento do registro
摘要: NetWorker: Como definir o tempo de truncamento ou substituição do registro.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
É necessário definir os registros do NetWorker para rollover diariamente, em vez de permitir que eles cresçam.
原因
.
解析度
Execute nsradmin no servidor:
nsradmin -p nsrexecd -s localhost
NetWorker administration program.
Use the "help" command for help, "visual" for full-screen mode.
nsradmin> p type: NSR log
Configurações atuais:
type: NSR log;
administrator: root, "user=root,host=server.domain.com";
owner: NMC Log File;
maximum size MB: 2;
maximum versions: 10;
runtime rendered log: ;
runtime rollover by size: Disabled;
runtime rollover by time: Disabled;
name: gstd.raw;
log path: /opt/lgtonmc/logs/gstd.raw;
type: NSR log;
administrator: root, "user=root,host=server.domain.com ";
owner: NetWorker;
maximum size MB: 2;
maximum versions: 10;
runtime rendered log: ;
runtime rollover by size: Disabled;
runtime rollover by time: Disabled;
name: daemon.raw;
log path: /nsr/logs/daemon.raw;
Para atualizar o horário:
nsradmin> update runtime rollover by time: "17:00"
runtime rollover by time: "17:00";
Update? y
updated resource id 14.0.236.7.47.0.0.0.11.30.125.83.192.168.123.102(3)
runtime rollover by time: "17:00";
Update? y
updated resource id 13.0.236.7.47.0.0.0.11.30.125.83.192.168.123.102(3)
nsradmin>
其他資訊
A hora real de rotação dos logs pode ser de até uma hora após o horário especificado, pois o horário de rotação de logs é verificado de hora em hora após o início do NetWorker.
Portanto, no exemplo acima, do NetWorker iniciado em digamos hh:35, o rodízio de logs ocorre às 17:35 diariamente.