MD Series: Controller Firmware Update for MD3000

摘要: How to do a Controller Firmware Update for a MD3000 or MD3000i.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

 
SLN316732_en_US__1icon Please Note before Update:
Do a backup of your data!
- The process of updates could take up to 30 minutes and both controllers will be restarted.
- For the update the storage has to be in the optimal-state.
- We recommend to do the Update during Downtime, because the IO will be stopped during the update
- Check the compatibility-guide of your Software-/OS-vendor if the Firmware is approved.
 

原因

-

解析度

1. Download the needed Firmware and Resource-DVD. 2. Install the newest Resource-CD/DVD.
Uninstall the older Version of the Modular Disk Storage Manager before you begin. Be aware that in this Version the multipath driver will be also uninstalled in this Situation - If you run the update on an attached Host the SAS-connection will be interrupted immediately.
  • Full Installation - includes the MDSM, MD cross generation update utility and the multipath driver (for server with storage-access and management)
  • Host Installation - includes only the multipath driver (for Server with storage-access but no management)
  • Management Station - includes only the MDSM and the MD cross generation update utility (for server/client with management only)
3. Extract the downloaded controller-firmware
4. Update the firmware as follows:
1. Open the Modular Disk Storage Manager (MDSM) and connect to the storage you want to update.
2. Choose the tab Support.
3. Choose in there the item Download Firmware and in the appearing window Browse to choose the firmware update.
The update utility will check the Major Event Log for actually existing issues. If there are failure-entries you will get a message. In this Case save and clear the MEL and the update will run.
4. For the RAID-Controller-Firmware choose the file with the ending *.dlp. Additionally, select the check-box Transfer NVSRAM with Raid controller module Firmware and provide the path to the NVSRAM-file via Browse.
Be aware that you have to check if you use a Single- or Dual-Controller-Configuration. Choose the right package according to the following table:
  MD3000 MD3000i
Raid-Controller FIRMWARE MD3000_FW_RC_07353964_133x.dlp MD3000i_FW_RC_06701760_1532.dlp
NVSRAM (Dual-Controller) Default-MD3000-N133X-75890-005.dlp Dual_Controller_MD3000i_N1532-670890-001.dlp
NVSRAM (Single-Controller) Single-port-clustering-MD3000-N133X-735890-705.dlp Single_Controller_MD3000i_N1532-670890-901.dlp
5. Start the update by clicking Transfer.
This process can take up to 30 Minutes.
6. Also update the firmware of the hard drives after the controller update finished fine.
Be Aware, that this is only recommended to do in a Downtime!
1. Download the HDD-firmware (Download) and extract the file.
2. Start the Modular Disk Storage Manager (MDSM).
3. Choose the Tab Support.
4. Use the Item Download Firmware.
5. Now choose Download Physical Disk Firmware.
6. In the window, which now appears, you will find the information which firmware-packages are installed in the moment for the physical drives.
7. Now open the ReadMe.txt, which is located in the extracted folder.
8. In that file you can search for the shown Firmware and you will find the actual package according this firmware.
9. If you use Add... you can attach the needed update from the folder.
10. Than you can also add additional packages for the different HDD-types by clicking Add... again.
11. Now click Next.
12. In the following window you will see a survey with the compatible HDD. Select the box Choose All and click the Finish-button. Now all updates will be enforced to the drives.

受影響的產品

Dell PowerVault MD3000 with Red Hat Enterprise Linux HA Clusters, Dell PowerVault MD3000 with Windows HA Clusters, Dell PowerVault MD3000i with Windows HA Clusters, PowerVault MD3000, PowerVault MD3000i