BigSwitch ZTD does not complete when using OS10 as p-network switch.

摘要: The DellEMC OS10 based switch as the p-network switch for a BigSwitch Fabric. The BCF or BMF switches may not fully boot and connect to the controller in a switchlight operating system. The boot stops at the ZTD discovery. ...

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

 

The controller and switches can ping each other IPv6 link local address. However, the process still does not fully complete. This can occur when the IPv6 packet crosses between switches such as the topology below. 

P-Switch-Topology


 

 

 

 

原因

The MLD snooping will not forward the ipv6 ND packets across the port-channel between switches. 

解析度

To resolve this issue the following commands globally on both switches:

OS10(config)# no ip igmp snooping enable

OS10(config)# no ipv6 mld snooping enable

Dell EMC OS10 has IGMP snooping and IPv6 MLD snooping enabled by default. This can result in the IPv6 discovery frames from Switchlight to the controller to be intercepted between switches.

受影響的產品

PowerSwitch S3048-ON, Dell EMC BSN Controller Node, Dell EMC BSN Controller VM, PowerSwitch S4048T-ON, PowerSwitch S4148F-ON/S4148T-ON/S4148FE-ON, PowerSwitch Z9332F-ON, SmartFabric OS10 Software
文章屬性
文章編號: 000132960
文章類型: Solution
上次修改時間: 11 10月 2023
版本:  5
向其他 Dell 使用者尋求您問題的答案
支援服務