How to change the ServiceTag of a PowerVault TL2000 or TL4000

摘要: How to change or correct the ServiceTag of a TL2000/TL4000

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

-

原因

-

解析度

Table of Contents

1. Description
2. Solution
3. Further Information

 


Description

A Service Tag is a unique number given to Dell products that is often found on the bottom, side, or back of the product. More information on how to locate your Service Tag can be found here. If the Library Controller Card (LCC) on the PowerVault TL2000 or TL4000 is serviced, the Service Tag may change. In this case it is possible to change the Service Tag. If the Service Tag is not displayed in the Web Interface, it is possible to correct it. This article explains how to amend the Service Tag if it has not been set or is incorrect after a repair.

SLN313981_en_US__1TagChange01
Figure 1: TL4000 LCD display

 


Solution

Please follow the directions below to change the Service Tag. The procedure is split into two sections. Firstly Preparing the Tape Library for access and, secondly, using the PuTTY program to access the device and change the Service Tag. PuTTY is an SSH and telnet client used to directly access the library in order to perform the procedures below. You can download PuTTY here.

Prepare the Tape Library for access

Use the directional buttons on the front bezel (Fig. 2) to interact with the LCD display and access the menu.

SLN313981_en_US__2image(9522)
Figure 2: Directional buttons and legend
 

  1. Press (← enter) one time to go to the main menu.
    SLN313981_en_US__3TagChange03
    Figure 3:  LCD display - Main Menu

     
  2. With (- down), go to Service and press (← enter).
    SLN313981_en_US__4TagChange04
    Figure 4:
    LCD display - Main Menu, Service Option

     
  3. With (-down), go to the last option Telnet Service Port and press (← enter).
    SLN313981_en_US__5TagChange05
    Figure 5:
    Service Option, Telnet Service Port

     
  4. Confirm with (← enter) on Proceed.
     SLN313981_en_US__6TagChange06
    Figure 6: Enable telnet port, confirmation

     
  5. A message will confirm that the command is running. This message will disappear after a short time.
    SLN313981_en_US__7TagChange07
    Figure 7: Informational, command successful


     

Connecting to the TL2000 or TL4000 with Putty

 

  1. Select the IP of the library and set the Connection type to Telnet.
    SLN313981_en_US__8putty_png-550x0
    Figure 8: PuTTY Configuration Screen
     
  2. Click Open to start the connection. The PuTTY command prompt window will appear.
    SLN313981_en_US__9TagChange08
    Figure 9: PuTTY command prompt window
     
  3. At first, log in as an administrator. To do this, use the command "login". Standard user: admin Standard password: secure. If your login is successful the window will display "login ok".
    SLN313981_en_US__10TagChange09
    Figure 10: PuTTY command prompt window, user logged in
     
  4. Use the command "STAG" followed by the desired Service Tag in quotations. In the example below "TEST123" is used as the Service Tag. This will change the Service Tag. It is imperative that you use the Service Tag that is shown on your system chassis. Failure to do so may result in issues with support.
    SLN313981_en_US__11TagChange10
    Figure 11: PuTTY command prompt window, STAG command syntax
  5. The new Service Tag will be displayed after a new login to the TL2000 or TL4000 web interface.


 


Further Information

  • PuTTY is an SSH and telnet client, developed originally by Simon Tatham for the Windows platform. PuTTY is open source software that is available with source code and is developed and supported by a group of volunteers. It is not a Dell Technologies tool.