GDDR: When running script GDDRPA23 the secondary site was not displayed in the banner correctly

摘要: GDDR: When running script GDDRPA23 the secondary site was not displayed in the banner correctly

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

Script GDDRPA23, in a STAR with AutoSwap configuration, was automatically submitted by the GDDR Event Manager (EVM) to resume ConGroup from DC2 to DC1 and the secondary site was not displayed in the banner correctly.  An '*' was displayed instead of DC1.

09.35.23 JOB31056 +GDDO041I GDDR Confirmation ===> 799
799 **************************************************
799 *                                                *
799 * Please Confirm Resume ConGroup                 *
799 *                                                *
799 *                                                *
799 *                                                *
799 * Secondary DASD Site: *                         *
799 *                                                *
799 **************************************************
09.35.23 JOB31056 +GDDO042A Please Confirm Resume ConGroup (Yes/No):
The script was automatically submitted by the EVM.
01MAR 09:00:05 CONSOLE  $HASP100 GDDRPA23 ON INTRDR      GDDR-JOB              FROM STCnnnnn GDDREVM
The issue occurs if the script is submitted manually using the
F GDDRMAIN,SCRIPT,GDDRPA23 
command.

原因

This is a software issue.

解析度

Permanent Fix:
  • For GDDR 6.0, PTF GD60020 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.

受影響的產品

Geographically Dispersed Disaster Restart (GDDR)