IO 負載高時出現 ESXi 紫色畫面

摘要: 當 I/O 負載高時,會隨機出現紫色畫面。沒有明顯的 SAN 問題或陣列相關問題。

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

環境:硬體 Dell 9116 交換器
VMware 作業系統:ESXi 任何版本 (第一次出現在 ESXi 7.0.3 中)

紫色螢幕之前有許多「路徑失敗」和「路徑有疑問」:

紫色螢幕的螢幕截圖:
VMware ESXi 7.0.3 [Releasebuild-21313628 x86_64]
#PF Exception 14 in world 2496356:vmm1:VA1PWCS IP 0x420023bf41db addr 0x28
PTEs:0x0;
cr0=0x80050031 cr2=0x28 cr3=0x815439b000 cr4=0x152668
FMS=06/55/7 uCode=0x5003302
frame=0x453a3061b730 ip=0x420023bf41db err=0x0 rflags=0x10206
rax=0x0 rbx=0x431655444ec0 rcx=0x76
rdx=0x49 rbp=0xc rsi=0x420023c91d46
rdi=0x4309a8b1da20 r8=0x1 r9=0x78a78c
r10=0xd78a78c r11=0x453a3061b640 r12=0x5fc
r13=0x43165559f160 r14=0x0 r15=0x1
*PCPU11:2496356/vmm1:VA1PWCSQL840
PCPU  0: SVVVVVVVVVVVVVVVSVSVVSVVVSVSVSSV
Code start: 0x420022c00000 VMC uptime: 22:18:04:37:412
0x453a3061b7f0:[0x420023bf41db]qedfc_process_error_detect@(qedf)#<None>+0x537 stack: 0x41ffe2ceb830
0x453a3061b840:[0x420023bd01da]qedfc_fp_process_cqes@(qedf)#<None>+0x47f stack: 0x420022cddf68
0x453a3061b890:[0x420023bd08a3]qed_msix_fp_int@(qedf)#<None>+0x18 stack: 0x4302b5832580
0x453a3061b8b0:[0x420022cde0e3]IntrCookieBH@vmkernel#nover+0x17c stack: 0x453a3061b8d0
0x453a3061b940:[0x420022cc0367]BH_DrainAndDisableInterrupts@vmkernel#nover+0x170 stack: 0x0
0x453a3061b9c0:[0x420022cdfce6]IntrCookie_VmkernelInterrupt@vmkernel#nover+0xb3 stack: 0xffffffffffffff8a
0x453a3061b9e0:[0x420022d55aac]IDT_IntrHandler@vmkernel#nover+0x9d stack: 0x0
0x453a3061ba00:[0x420022d4e067]gate_entry@vmkernel#nover+0x68 stack: 0x0
0x453a3061bac8:[0x420022c84608]Power_ArchPerformWait@vmkernel#nover+0x70 stack: 0x420042c00980
0x453a3061bad0:[0x420022c84776]Power_ArchSetCState@vmkernel#nover+0x8f stack: 0x0
0x453a3061bb20:[0x420022fae43c]CpuSchedIdleLoopInt@vmkernel#nover+0x275 stack: 0x420042c00100
0x453a3061bb90:[0x420022fb2502]CpuSchedDispatch@vmkernel#nover+0x1aff stack: 0x420042c00140
0x453a3061bdd0:[0x420022fb3257]CpuSchedWait@vmkernel#nover+0x2f4 stack: 0x7
0x453a3061bf50:[0x420022fb37ee]CpuSched_VcpuHalt@vmkernel#nover+0x13f stack: 0x453a3061f000
0x453a3061bfa0:[0x420022d2d313]VMMVMKCall_Call@vmkernel#nover+0x108 stack: 0x0
0x453a3061bfe0:[0x420022d59489]VMKVMM_ArchEnterVMKernel@vmkernel#nover+0xe stack: 0x420022d5947c
base fs=0x0 gs=0x420042c00000 Kgs=0x0

原因

此問題經判定為 9116 交換器問題 (每組機箱中有兩個這樣的交換器),此問題會混淆 FCoE 資料。

解析度

如果您遇到此問題,請將 MX7000 機箱、交換器和刀鋒伺服器上的韌體升級至最新的合格版本。

受影響的產品

PowerEdge MX7000

產品

VMware
文章屬性
文章編號: 000214640
文章類型: Solution
上次修改時間: 13 5月 2025
版本:  5
向其他 Dell 使用者尋求您問題的答案
支援服務