NMC UI-popupmeddelande "Internal Server Error. Please see console log for more details."

摘要: NMC UI-popupmeddelande "Internal Server Error. Please see console log for more details."

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

  • I NetWorker Management Console-användargränssnittet (NMC) visas popupmeddelandet "Internal Server Error. Please refer to console log for more details."
  • Meddelandet öppnas när du klickar på resurser på fliken Skydd i NMC.
  • Principer på fliken Skydd visas inte i NMC.
  • NMC loggade ett Java-undantag
java.lang.NullPointerException
at COM.legato.networker.protection.DataProtectionPolicy.convertPeriodActivityType(DataProtectionPolicy.java:1470)
at COM.legato.networker.protection.DataProtectionPolicy.actionSequenceJSONModelToUIView(DataProtectionPolicy.java:1616)
at COM.legato.networker.protection.DataProtectionPolicy.policyJSONModelToUIView(DataProtectionPolicy.java:1438)
at COM.legato.networker.protection.DataProtectionPolicy.
  • Principer visas i det HTML-baserade NetWorker-webbanvändargränssnittet (NWUI)

原因

Felaktigt schema har konfigurerats i resursen för NSR Protection Policy. Schemat som konfigurerats i policyn finns inte som en NSR-schemaresurs.

解析度

Redigera policyn för att återspegla rätt schema. Jämför namnet på schemat som konfigurerats i policyn med namnen i NSR-schemaresursen.
Om schemat i policyn till exempel är "db_log" i NSR-schemat kallas resursen "DB_LOG" och ersätter schemat i policyn med "DB_LOG".