DSA-2024-127: Security Update for Dell Data Protection Central for Third-Party Component Vulnerabilities
摘要: Dell Data Protection Central remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
影響
High
詳細資料
| Third-party Component | CVEs | More Information |
|---|---|---|
| SUSE Linux Enterprise Server 12 SP5 | CVE-2015-1782, CVE-2020-16135, CVE-2021-33631, CVE-2021-3634, CVE-2021-3696, CVE-2023-1667, CVE-2023-2283, CVE-2023-37536, CVE-2023-46838, CVE-2023-47233, CVE-2023-51042, CVE-2023-51043, CVE-2023-51385, CVE-2023-51780, CVE-2023-51782, CVE-2023-5388, CVE-2023-6004, CVE-2023-6040, CVE-2023-6356, CVE-2023-6535, CVE-2023-6536, CVE-2023-6918,CVE-2023-7207, CVE-2024-0340, CVE-2024-0775, CVE-2024-1086, CVE-2024-20918, CVE-2024-20919, CVE-2024-20921, CVE-2024-20926, CVE-2024-20945, CVE-2024-20952, CVE-2024-21626, CVE-2024-25062 | See SUSE link below for individual scores for each CVE https://www.suse.com/security/cve/ |
受影響的產品與補救措施
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
|---|---|---|---|---|
| Dell Data Protection Central | Data Protection Central OS Update (SUSE SLES 12 SP5) | Version 19.5 through 19.10.0-4 with Data Protection Central OS Update prior to dpc-osupdate-1.1.17-1 | Version 19.5 through 19.10.0-4 with Data Protection Central OS Update dpc-osupdate-1.1.18-1 |
Apply Latest Data Protection Central OS Update |
| Integrated Data Protection Appliance (PowerProtect DP Series) | Data Protection Central OS Update for Power Protect DP Series Appliances | Version 2.7.6 and prior | Version 2.7.6 with Data Protection Central OS Update dpc-osupdate-1.1.18-1 | Apply Latest Data Protection Central OS Update |
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
|---|---|---|---|---|
| Dell Data Protection Central | Data Protection Central OS Update (SUSE SLES 12 SP5) | Version 19.5 through 19.10.0-4 with Data Protection Central OS Update prior to dpc-osupdate-1.1.17-1 | Version 19.5 through 19.10.0-4 with Data Protection Central OS Update dpc-osupdate-1.1.18-1 |
Apply Latest Data Protection Central OS Update |
| Integrated Data Protection Appliance (PowerProtect DP Series) | Data Protection Central OS Update for Power Protect DP Series Appliances | Version 2.7.6 and prior | Version 2.7.6 with Data Protection Central OS Update dpc-osupdate-1.1.18-1 | Apply Latest Data Protection Central OS Update |
- Platform: SUSE Linux Enterprise Server 12 SP5
- Versions 19.5 through 19.10.0-4 covers DPC version 19.5.x, 19.6.x, 19.7.x, 19.8.x, 19.9.x, 19.10.x.
- To determine the version of Data Protection Central OS Update, examine the /etc/dpc-osupdates file for version information.
- The DPC version number remains the same in the DPC OS Update distribution that provides the fixes. Examine the /etc/dpc-osupdates file to confirm execution of DPC OS Update; this file will contain the line: version=1.1.18-1
See the latest ‘Data Protection Central OS Update’ file in https://www.dell.com/support/home/en-us/product-support/product/data-protection-central/drivers
See the latest ‘Data Protection Central OS Updates Release Notes’ in https://www.dell.com/support/home/en-us/product-support/product/data-protection-central/docs
The DPC version number remains the same in the DPC OS Update distribution that provides the fixes. Examine the /etc/dpc-osupdate file to confirm execution of DPC OS Update; this file will contain the line:
version=1.1.18-1
修訂歷史記錄
| Revision | Date | Description |
|---|---|---|
| 1.0 | 2024-03-19 | Initial Release |