PowerScale Gen6/MLK 節點無法開機,GEOM 啟動失敗

摘要: 節點無法開機,並顯示「GEOM 啟動失敗」訊息。

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

將節點因任何原因重新開機時,節點無法重新連線。如果使用零數據機電纜連接到節點,則引導序列將以類似於以下內容的消息結束:

kldload: acpi_sel0: <System Error Log (SEL) GPE Hook> numa-domain 0 on acpi0
an error occurred while loading module lnv. Please check dmesg(8) for more details.
Early ELF ldconfig path: /lib:/usr/lib:/usr/lib/compat:/usr/local/lib:/usr/likewise/lib:/usr/local/apache2/lib:/usr/local/apache2/bin:/usr/local/lib/compat/pkg:/usr/lib:/usr/likewise/lib:/usr/local/lib/compat/pkg:/usr/local/lib/perl5/5.32/mach/CORE:/usr/local/llvm40/lib
<isi_rc> Executing script hostid
Setting hostuuid: 03000200-0400-0500-0006-0c0000002000.
Setting hostid: 0x0fb9b77f.
Executing GEOM bootdisk startup...
 
GEOM start failed
To prevent a DL situation, contact Dell EMC Customer Support immediately:
United States: 1 800 782 4362 (1 800 SVC 4EMC)
Canada: 1 800 543 4782 (1 800 543 4SVC)
Worldwide Country Code: 1 508 497 7901
 
 
Command Options:
1) Enter recovery shell
2) Continue booting
3) Reboot
option>

如果您進入復原 Shell 並檢查已掛接的檔案系統,root 會掛載為唯讀:

# mount
/dev/mirror/root1 on / (ufs, local, read-only)
devfs on /dev (devfs, local)
#

檢查開機磁碟分割,您會看到類似以下內容:

# gpart list | grep -B9 bootdisk | egrep "uuid|Name|label"|paste - - -
4. Name: da16p4    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid
4. Name: da17p4    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid
4. Name: da18p4    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid
3. Name: da19p4    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid
4. Name: da21p4    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid
2. Name: ada0p2    rawuuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx           label: bootdiskid

原因

ada0 上的開機分割區無效。Gen6/MLK 節點不應在該裝置上具有開機分割區。

 

解析度

請聯絡 技術支援 ,並引用此知識庫文件。

受影響的產品

Isilon Gen6, PowerScale Archive A300, PowerScale Archive A3000, PowerScale A310, PowerScale A3100, PowerScale Hybrid H700, PowerScale Hybrid H7000, PowerScale H710, PowerScale H7100, PowerScale PA110
文章屬性
文章編號: 000337624
文章類型: Solution
上次修改時間: 24 12月 2025
版本:  2
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。