DSA-2025-339: Security Update for Dell Avamar Data Store Gen5A Multiple Third-Party Component Vulnerabilities
摘要: Dell Avamar Data Store Gen5A remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
影響
Critical
詳細資料
| Third-party Component | CVEs | More Information |
| Dell PowerEdge Server BIOS | CVE-2024-38796, CVE-2024-28956, CVE-2024-45332, CVE-2024-48012 | DSA-2025-038, DSA-2025-041, DSA-2025-156, DSA-2025-046 |
| Integrated Dell Remote Access Controller (iDRAC) | CVE-2025-26466, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50602, CVE-2024-2961, CVE-2023-6780, CVE-2024-52533, CVE-2023-52340, CVE-2024-42154 | DSA-2025-145. DSA-2025-146, DSA-2024-460 |
受影響的產品與補救措施
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
Notes:
- This security includes both newly remedied and past vulnerabilities included in this cumulative update.
- Dell recommends upgrading to the latest release/version of your product. To schedule a platform security patch installation or firmware upgrade, please contact Dell Customer Support.
Known Issue:
- Upgrading directly to the August 2025 firmware, which includes BIOS 2.24.0, may fail on systems running BIOS versions prior to 2.12.2, due to compatibility constraints.
Required Action:
- To verify the BIOS version, run the following command in the Avamar console as an admin/root user:
omreport system version
- If the BIOS version is earlier than 2.12.2 contact Dell Customer Support to apply the September 2021 firmware block (AVP: Gen5aSep2021Blk338753.avp) before installing the August 2025 firmware.
因應措施與緩解措施
None
修訂歷史記錄
| Revision | Date | Description |
| 1.0 | 2025-09-01 | Initial Release |
| 2.0 | 2025-10-06 | Replaced the NVD generic search link with the PowerEdge and iDrac advisories |
| 3.0 | 2025-10-22 | Major update to include CVE-2024-48012 |
| 4.0 | 2025-12-30 | Updated 'Additional Information' section |
相關資訊
法律免責聲明
受影響的產品
Avamar, Avamar Data Store, Avamar Data Store Gen5A, Avamar Server文章屬性
文章編號: 000362542
文章類型: Dell Security Advisory
上次修改時間: 30 12月 2025
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。