PowerEdge:使用 PERCCLI 管理 PowerEdge RAID 控制器

摘要: 本文提供如何使用 PERCCLI 公用程式管理 Dell PowerEdge RAID 控制器 (PERC) 的相關資訊。

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

說明

使用 PERCCLI 管理 PERC 控制器

 

虛擬磁碟 (VD) 管理

使用以下命令控制一致性檢查、保留的快取和虛擬磁碟:

  • 暫停一致性檢查
  • 恢復一致性檢查
  • 顯示一致性檢查狀態
  • 啟動一致性檢查
  • 停止一致性檢查
  • 刪除保留的快取
  • 顯示保留的快取
  • 刪除虛擬磁碟
  • 建立虛擬磁碟
# Pause consistency check
perccli /cX/vY pause cc

# Resume consistency check
perccli /cX/vY resume cc

# Show consistency check status
perccli /cX/vY show cc

# Start consistency check (add "force" if required)
perccli /cX/vY start cc [force]

# Stop consistency check
perccli /cX/vY stop cc

# Delete preserved cache (add "force" if required)
perccli /cX/vY delete preservedCache [force]

# Show preserved cache
perccli /cX show preservedCache

# Delete a virtual disk (use "all" to delete all VDs)
perccli /cX/vY|all del

# Create a virtual disk (example)
perccli /cX add vd r5 size=500GB name=VD1 drives=1:0-3 pdperarray=4 pdcache=on wt wb strip=128 force
警示: 使用 force 可能會導致資料遺失。執行前請先確認目標磁碟機。

 

 

 

實體磁碟管理

使用下列命令來檢視、設定、尋找及指派實體磁碟的熱備援。

  • 顯示磁碟機資訊
  • 設定磁碟機狀態 (JBOD、良好、離線、線上)
  • 啟動/停止驅動器定位 LED
  • 新增或刪除熱備援磁碟機
  • 管理外部組態
# Show a specific drive (controller X, enclosure Y, slot Z)
perccli /cX/eY/sZ show

# Show all drives on a controller
perccli /cX/eall/sall show

# Show all drives with detailed information
perccli /cX/eY/sZ|sall show all

# Show drives in JBOD mode
perccli /cX/eY/sall show jbod
perccli /cX/eY/sZ show jbod

# Set a drive to JBOD
perccli /cX/eY/sZ set jbod

# Set a drive to GOOD (add "force" if required)
perccli /cX/eY/sZ set good [force]

# Set a drive OFFLINE
perccli /cX/eY/sZ set offline

# Set a drive ONLINE
perccli /cX/eY/sZ set online

# Start locate LED on a drive
perccli /cX/eY/sZ start locate

# Stop locate LED on a drive
perccli /cX/eY/sZ stop locate

# Add a hot‑spare drive (optional DG list, enclosure affinity, non‑revertible)
perccli /cX/eY/sZ add hotsparedrive [DGs=0,1,2][enclaffinity][nonrevertible]

# Delete a hot‑spare drive
perccli /cX/eY/sZ delete hotsparedrive

# Delete foreign configuration (add security key if required)
perccli /cX/fx|fall del [securitykey=sssssssssss]

# Import foreign configuration (preview optional)
perccli /cX/fx|fall import [preview][securitykey=sssssssssss]

# Show foreign configuration (add "all" to list all)
perccli /cX/fx|fall show [all][securitykey=sssssssssss]
警告: 刪除外部組態會移除所有擱置中的 RAID 中繼資料。確定不再需要該組態後再繼續。

 

選項 值範圍 說明
rXX RAID [0|1|5|6|10|50|60] Sets the RAID type of the configuration.
size Maximum size based on the physical drives and RAID level. Sets the size of each virtual drive. Default is the capacity of all referenced disks.
name 15 characters Specifies the drive name for each virtual drive.
drives Valid enclosure number and slot numbers (e:s|e:s-x|e:s-x,y) Defines which physical drives belong to the VD. e = enclosure ID, s = slot.
pdperarray 0‑15 Number of physical drives per array. Default is chosen automatically.
sed Creates security‑enabled drives.
pdcache on|off|default Enables or disables physical‑drive cache.
pi Enables protection information.
dimmerswitch default|automatic|none|maximum|maxnocache Specifies power‑saving policy for the logical device.
wt|wb wt (write‑through) or wb (write‑back) Sets write policy. Write‑back is default.
nora|ra ra (read‑ahead) or nora (no read‑ahead) Controls read‑ahead. Read‑ahead is default.
cachedbadbbu|nocachedbadbbu Enable/disable caching when BBU is faulty. Disabled by default.
strip 8,16,32,64,128,256,512,1024 Sets the strip size for the RAID configuration.
aftervd Valid virtual drive number Creates the VD in the free slot next to the specified VD.
spares List of physical drives Assigns spare drives to the disk group.
force Forces addition of a security‑capable drive without security.

 

 

若要安裝 PERCCLI,請參閱:PowerEdge:如何在 Red Hat Linux、Ubuntu Linux、VMware ESXi 和 Windows Server 上安裝 PERCCLI 公用程式

其他資訊

受影響的產品

PowerEdge RAID Controller H345, PowerEdge RAID Controller H350 Adapter SAS, PowerEdge RAID Controller H355 Front SAS, PowerEdge RAID Controller H355 Adapter SAS, PowerEdge RAID Controller H365i Adapter, PowerEdge RAID Controller H365i Front DC-MHS , PowerEdge RAID Controller H730P MX, PowerEdge RAID Controller H745, PowerEdge RAID Controller H745P MX, PowerEdge RAID Controller H750 Adapter SAS, PowerEdge RAID Controller H755 Adapter, PowerEdge RAID Controller H755 MX Adapter, PowerEdge RAID Controller H755N Front NVMe, PowerEdge RAID Controller H755 Front SAS, PowerEdge RAID Controller H965i Adapter, PowerEdge RAID Controller H965i Front, PowerEdge RAID Controller H965i MX, PowerEdge RAID Controller H975i Front, PowerEdge RAID Controller H330, PowerEdge RAID Controller H730, PowerEdge RAID Controller H730P, PowerEdge RAID Controller H740P, PowerEdge RAID Controller H965e Adapter ...