iDRAC 8/7 v2.30.30.30 User’s Guide

Enabling serial connection IPMI mode using RACADM

To configure the IPMI mode, disable the RAC serial interface and then enable the IPMI mode using any of the following:
  • Using config command:
    racadm config -g cfgSerial -o cfgSerialConsoleEnable 0
    racadm config -g cfgIpmiSerial -o cfgIpmiSerialConnectionMode 
                                           < 0 
                                            or  1
                                           >
                                        

    where, 0 indicates Terminal mode and 1 indicates Basic mode.

  • Using set command:
    racadm set iDRAC.Serial.Enable 0
    racadm set iDRAC.IPMISerial.ConnectionMode 
                                           < 0 
                                            or  1
                                           >
                                        

    where, 0 indicates Terminal mode and 1 indicates Basic mode.