Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Autoconfigure behavior

The autoconfigure behavior automatically configures unconfigured drives during reboot and hot insertion. Unconfigured drives are configured according to the settings; but the configured drives remain unaffected. PERC 11 supports Off and Non–RAID settings.
Table 1. Autoconfigure behavior settingsThe following table describes the settings of autoconfigure behavior.
Settings Description
Off Autoconfigure behavior is turned off.
Non–RAID Unconfigured drives are configured as non–RAID disk during boot or during hot insertion; all the configured drives remain unaffected.
Off to Non–RAID disk Unconfigured drives are converted to non–RAID disks; all the configured drives remain unaffected.
Non–RAID disk to Off Unconfigured drives remain unconfigured good; all the configured drives remain unaffected.
NOTE: PERC H355 front SAS, PERC H355 adapter SAS, PERC H350 adapter SAS, and PERC H350 Mini Monolithic SAS converts an unconfigured good drive to non-RAID only if the drive has never been used before by that specific PERC.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\