Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Drive removal and insertion in the same slot generates a foreign configuration event

Issue:
When a drive which is part of a virtual disk is removed and reinserted into the same slot the drive goes through a transient state of being foreign for a short period of time before rebuilding.
Description:
This transient state could be reported as an event in management applications as A foreign configuration was detected on RAID Controller is SL x, where x is the slot of the RAID controller.
Corrective Action:
No action is required on the foreign configuration state of the drive as it is transient and the controller handles the event automatically.