Fixed Issues
Related to Replication and Live Volume
The following replication and Live Volume issues are fixed in Storage Center7.2:
Table 1. Fixed Replication
and Live Volume Issues in Storage Center 7.2.50Replication and Live Volume issues fixed in Storage Center 7.2.50
Issue
Description
SCOS-46819
On a storage system with Automatic Fail Over Live Volumes, a Live Volume fail over might cause an error because IORP codes are not transferred back to the originating controller over IPC.
SCOS-46572
The source and destination volumes associated with a replication might become different sizes if the source volume fails to expand due to Storage Center scalability limitations.
Table 2. Fixed Replication
and Live Volume Issues in Storage Center 7.2.40Replication and Live Volume issues fixed in Storage Center 7.2.40
Issue
Description
SCOS-45553
Storage Center might be able to manage replication volumes as physical drives.
SCOS-18102
The status of a cross-platform replication partner
changes to down when the number of snapshots exceed 1025.
Table 3. Fixed Replication
and Live Volume Issues in Storage Center 7.2.10Replication and Live Volume issues fixed in Storage Center 7.2.10
Issue
Description
SCOS-40210
When performing an update from Storage Center 6.7.5
to 7.1.4 on a storage system with a secondary Live Volume, I/O might
become stuck on volumes on the source system.
SCOS-36665
A controller reset might occur while attempting
to fail over a Windows cluster on an RDM volume mapped to non-unified
ESXi hosts when using Live Volume High Consistency.
SCOS-35656
Live Volume proxy disk space might be counted
towards the total available system disk space.
SCOS-32134
Access to a volume might be lost if out of memory
errors occur before the replication enters the suspending state.
SCOS-7793
A storage system might fail to delete a replication
when the QoS node is blocked and there is outstanding I/O.
Table 4. Fixed Replication
and Live Volume Issues in Storage Center 7.2.1Replication and Live Volume issues fixed in Storage Center 7.2.1
Issue
Description
SCOS-22156
The VVols feature in ESXi 6.0 Update 2 fails to
work properly with Storage Center 7.1.2.