Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

Prerequisites for removing the Shared PERC 8 External card

  • CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the system.
Perform the following steps to enable recovery in the event the part replacement process fails:
  1. Follow the operating system procedure to back up all data from the shared storage drives.
    • CAUTION: The part replacement procedure is complex and can put your data at risk if mistakes are made. It is imperative that critical data is backed up prior to starting the procedure.
  2. Document your virtual drive configuration and mapping information by performing the following steps:
    1. Open CLI terminal and run the command racadm raid get vdisks –o . Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
    2. Click Chassis Overview → Storage → Virtual Disks → Assign to view the virtual disk mapping by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
    3. Click Chassis Overview → Storage → Virtual Disks to get the virtual disk configuration information by the CMC GUI. Take a screen shot of the results page and save the captured screen shot to a location of choice, or write down the information and store it in a safe, secure location.
  3. Click Chassis Overview → Storage → Controllers to view the firmware version of the current Shared PERC 8 External card.
  4. Turn off the server modules using operating system commands or the CMC.
  5. Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet and peripherals.
  6. Remove the server modules and the shared storage hard drives from the PowerEdge VRTX system.
    • WARNING: To prevent damage to system components, do not stack system components together after removal. For information on electrostatic discharge (ESD) compliance, see Dell.com/regulatory_compliance.
    • NOTE: Label all server modules and hard drives before removal so that they can be replaced in the same slots.
  7. If applicable, rotate the system feet inward and place the system on its side on a flat surface, with the cover release latch side on top.
  8. Open the system.

Rate this content