Dell Shared PowerEdge RAID Controller 8 Cards For Dell PowerEdge VRTX Systems User’s Guide

Rebuilding a Failed physical disk

Issue:
Rebuilding a physical disk after one of them is in a failed state.
Corrective Action:
If you have configured hot spares, the Shared PERC 8 card automatically tries to rebuild a physical disk that is in a failed state. The automatic rebuild is not available if there is no hot spare with enough capacity to rebuild the failed physical disk. You must make sure a physical disk with enough storage in the subsystem is set as a hot spare for rebuilding the physical disk.