Dell PowerVault MD 32XX/36XX Series Storage Arrays CLI Guide

PDF

Setting RAID Controller Module Operational Mode

A RAID controller module has three operational modes:
  • Online
  • Offline
  • Service
  • CAUTION: Placing a RAID controller module offline can cause loss of data.
Placing a RAID controller module online sets it to the Optimal state and makes it active and available for I/O operations. Placing a RAID controller module offline makes it unavailable for I/O operations and moves its disk groups to the other RAID controller module if failover protection is enabled.

Taking a RAID controller module offline can seriously impact data integrity and storage array operation.

If you take a RAID controller module offline, the second RAID controller module in the pair takes over. Disk groups and their associated virtual disks that were assigned to the offline RAID controller module are automatically reassigned to the remaining RAID controller module.
  • CAUTION: Place a RAID controller module in Service mode only under the direction of Technical Support.
Use Service mode when you want to perform an operation, such as replacing a RAID controller module. Placing a RAID controller module in Service mode makes it unavailable for I/O operations. Placing a RAID controller module in Service mode also moves the disk groups from the RAID controller module to the second RAID controller module without affecting the disk groups’ preferred path. Moving disk groups might significantly reduce performance. The disk groups are automatically transferred back to the preferred RAID controller module when it is placed back online.
  • CAUTION: A multipath driver is required on all hosts and is the only supported configuration. If the multipath driver is not installed, the virtual disks are not accessible.
Before you place a RAID controller module in Service mode, ensure that a multipath driver is installed on all hosts using these virtual disks.
To change the operational mode of a RAID controller module, run the following command:
set controller [(0 | 1)] availability=(online | offline | serviceMode)

Évaluez ce contenu

Précis
Utile
Facile à comprendre
Avez-vous trouvé cet article utile ?
0/3000 characters
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez attribuer une note (1 à 5 étoiles).
  Veuillez indiquer si l’article a été utile ou non.
  Les commentaires ne doivent pas contenir les caractères spéciaux : <>()\