Hotplugging enclosures in fault-tolerant chassis

  1. Make sure that slots 5 and 6 chassis are not fault-tolerant.
  2. Disconnect the enclosures.
  3. Change the status of slots 5 and 6 to fault-tolerant mode.
  4. Reconnect the enclosures in fault-tolerant cabling.
Power cycle the chassis after disconnecting the enclosures and before reconnecting enclosures as, the drives retain the previous SCSI-3 Reservation until the chassis is power cycled.