Avançar para o conteúdo principal
  • Efetuar encomendas de forma rápida e fácil
  • Ver todas as encomendas e controlar o seu estado de expedição
  • Criar e aceder a uma lista dos seus produtos
  • Gerencie seus sites, produtos e contatos de nível de produto da Dell EMC usando o Company Administration.

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide

PDF

Example of Single-Appliance FC 10GbE Cluster Configuration

The following example shows the best-practices configuration for single-appliance Fibre Channel 10GbE clusters.

  • Client network – Each FS8600 controller has a connection to each stacked Ethernet switch.
  • Internal network – The FS8600 controllers are directly connected to each other with two twinax cables.
  • Fibre Channel SAN – Each FS8600 controller has a connection to each FC fabric (Storage Center fault domain).
Figure 1. Single-Appliance Fibre Channel 10GbE Cluster Configuration With an SC4020 Storage System Configuration of a single-appliance FC 10GbE cluster with an SC4020 storage system
  1. Client network
  2. Internal network
  3. Fibre Channel SAN switch
  4. SC4020 with 10Gb FC ports
  5. Client network connections
  6. FS8600 internal network connections
  7. Storage Center fault domain 1 connections
  8. Storage Center fault domain 2 connections