跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2122

Description
Redundancy degraded.
Severity
Warning / Non-critical
Cause and Action
Cause: One or more of the enclosure components has failed.

For example, a fan or power supply may have failed. Although the enclosure is currently operational, the failure of additional components could cause the enclosure to fail.

Action: Identify and replace the failed component. To identify the failed component, select the enclosure in the tree view and click the Health subtab. Any failed component is identified with a red X on the enclosure’s Health subtab. Alternatively, you can select the Storage object and click the Health subtab.

The controller status displayed on the Health subtab indicates whether a controller has a Failed or Degraded component.

See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.

Related Alert Information
Clear Alert Number: 2124

Related Alert Number: 2048

Local Response Agent (LRA) Number: 2090

SNMP Trap Numbers