Είδη
Μη έγκυρη καταχώριση. Χρησιμοποιήστε μόνο γράμματα, αριθμούς και τυχόν ειδικούς χαρακτήρες εκτός από <>)(%/;,=#-/*
30 από 231 εμφανίζονται
231 από 231 εμφανίζονται
This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Ενημερωμένοι: December 10, 2025
ID: 000127944
Learn how to create and export a SupportAssist Collection using iDRAC9 and iDRAC10 on Dell devices. Resolve technical issues with this step-by-step guide.
Ενημερωμένοι: December 08, 2025
ID: 000126308
This article provides information about how to boot past the Driver Health Manager Screen.
Ενημερωμένοι: December 23, 2025
ID: 000148089
It’s a common misconception that if a PowerEdge server fails to boot, doesn’t complete POST, or experiences other issues, the iDRAC will also be inaccessible. In reality, iDRAC is often still online and available to assist with troubleshooting—even if it was never configured beforehand. Leveraging iDRAC to review recent events, analyze logs, and collect a SupportAssist Collection (TSR) is critical for accelerating diagnosis and recovery.
Ενημερωμένοι: December 15, 2025
ID: 000401536
Storage components may not be displayed, or the status may appear as Unknown after upgrading iDRAC9 firmware to version 7.20.60.50 or 7.20.70.50.
Ενημερωμένοι: December 12, 2025
ID: 000388426
If the SYSVOL share is absent from every domain controller (DC) in an Active Directory (AD) domain, AD management consoles may give an error like this:
"An Active Directory domain controller (AD DC) for the domain <domain> could not be contacted."
If Distributed File System Replication (DFSR) is used to replicate SYSVOL data, the issue appears difficult to resolve. An authoritative sync of DFSR cannot be performed without the ADSI Edit console. Fortunately, the issue can be resolved by modifying the registry on the DC with the authoritative copy of SYSVOL. A different registry modification is then performed on the other DCs.
Ενημερωμένοι: December 10, 2025
ID: 000198564
This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss.
Ενημερωμένοι: December 09, 2025
ID: 000126418
This article provides the recommended steps to help troubleshoot memory-related events on Dell PowerEdge servers.
Ενημερωμένοι: December 08, 2025
ID: 000304931
This article explains how to use iDRAC Direct to manage your PowerEdge server.
Ενημερωμένοι: December 04, 2025
ID: 000130077
This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers, how physical drive LED indicators provide quick visual diagnostics, and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Ενημερωμένοι: December 04, 2025
ID: 000143247
Understand and troubleshoot PowerEdge hard disk drives, RAID, PowerEdge RAID Controller, and other storage hardware such as cables, backplane, so forth.
Ενημερωμένοι: December 03, 2025
ID: 000110444
This page explains the difference between drivers and firmware and how to update them on Dell PowerEdge Servers using different methods.
Ενημερωμένοι: December 02, 2025
ID: 000128194
The PowerEdge embedded LifeCycle Controller provides a simplified method for installation of supported Windows Server and Linux server operating systems with the OS Deployment feature.
This article explains how to use the iDRAC LifeCycle Controller to install a supported operating system on most Dell PowerEdge servers. Step-by-step instructions and OS installation videos for Windows Server, Ubuntu Server LTS, SUSE Linux Enterprise Server, or Red Hat Enterprise Linux installation with LifeCycle Controller
Ενημερωμένοι: December 02, 2025
ID: 000130160
This article explains the difference between a reset and a Power Drain.
Ενημερωμένοι: December 02, 2025
ID: 000175625
This article explains how to create a Virtual Disk using the System Settings menu.
Ενημερωμένοι: December 01, 2025
ID: 000178269
The user reported that the Power Supply Unit (PSU) has encountered issues when inserted into the server. It failed to power on the Dell PowerEdge R640 server, but the indicator on the PSU shows a green LED. Checking the TSR log finds the messages "PSU redundancy lost" or "The system board XXX voltage is out of range."
Ενημερωμένοι: November 28, 2025
ID: 000215889
This article provides the information of how to assign or unassign a global dedicated hot spare for a hard drive.
Ενημερωμένοι: November 25, 2025
ID: 000177797
Correctable and uncorrectable memory errors on PowerEdge Server with DDR4 and changes to troubleshooting steps
Ενημερωμένοι: November 25, 2025
ID: 000053203
This article provides information about Dell Boot Optimized Storage Solution (BOSS) PCIe cards. It also provides instructions for installing Windows, Red Hat, SuSE, Ubuntu, and related Linux distributions onto these cards.
Ενημερωμένοι: November 24, 2025
ID: 000177584
This article is a step-by-step guide on how to replace a hard drive.
Ενημερωμένοι: November 14, 2025
ID: 000143539
Dell PowerEdge Server remediation is available Intel® Ethernet Controllers & Adapters Vulnerability that may be exploited by malicious users to compromise the affected system.
Ενημερωμένοι: November 13, 2025
ID: 000390646
This article describes how to gather the necessary log files to troubleshoot a vSphere Tanzu issue.
Ενημερωμένοι: November 12, 2025
ID: 000187022
Find answers and resources to get started or do more from your MyService360 dashboard with enterprise services data analytics and visualizations.
Ενημερωμένοι: November 10, 2025
ID: 000124666
When running the nvidia-smi command, you may encounter a driver error stating that "nvidia-smi has failed because it could not communicate with the NVIDIA driver.
Ενημερωμένοι: November 08, 2025
ID: 000252982
Dell iDRAC9 and iDRAC10 remediations are available for an arbitrary file export vulnerability that could be exploited by malicious users to compromise the affected system.
Ενημερωμένοι: November 06, 2025
ID: 000384516
This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Ενημερωμένοι: November 05, 2025
ID: 000136481
Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Ενημερωμένοι: October 28, 2025
ID: 000381662
This article provides information about how to update your system's firmware from the Lifecycle Controller on Dell servers.
Ενημερωμένοι: October 28, 2025
ID: 000128133
This article provides guidance for the Dell System Update (DSU).
Ενημερωμένοι: October 21, 2025
ID: 000130590
The firmware of PowerEdge server hard drives is a critical component in the server system. Regularly updating and maintaining this firmware is essential for server performance, security, and compatibility.
Hard drive firmware updates can often fix known hardware faults and issues, address identified vulnerabilities and security problems, and potentially introduce new features, improvements, and enhancements.
Ενημερωμένοι: October 16, 2025
ID: 000226155