This article explains how to create and import an iDRAC certificate.
Ενημερωμένοι:  May 28, 2026 ID: 000120158

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Ενημερωμένοι:  May 25, 2026 ID: 000136481

This document answers questions about SupportAssist Enterprise.
Ενημερωμένοι:  May 27, 2026 ID: 000060848

The drive will assert due to a log full condition after the first power cycle when it reaches 70000 Power On Hours (POH). The drive will not process read or write commands once in this state.
Ενημερωμένοι:  May 25, 2026 ID: 000217034

PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Ενημερωμένοι:  May 24, 2026 ID: 000396285

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Ενημερωμένοι:  May 24, 2026 ID: 000391086

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Ενημερωμένοι:  May 24, 2026 ID: 000381662

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Ενημερωμένοι:  May 24, 2026 ID: 000379421

The article provides the solution to the firmware update errors for ConnectX-4 LX NICs SWB 76DNG version 14.32.21.02 & ConnectX-5 dual port SWB 1GF8G version 16.35.40.30.
Ενημερωμένοι:  May 24, 2026 ID: 000378312

This article provides information about the LIC008 error seen when importing the IDRAC License.
Ενημερωμένοι:  May 23, 2026 ID: 000353269

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Ενημερωμένοι:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Ενημερωμένοι:  May 23, 2026 ID: 000349127

Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Ενημερωμένοι:  May 23, 2026 ID: 000333265

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Ενημερωμένοι:  May 23, 2026 ID: 000321587

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Ενημερωμένοι:  May 23, 2026 ID: 000314166

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Ενημερωμένοι:  May 22, 2026 ID: 000256907

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Ενημερωμένοι:  May 22, 2026 ID: 000246018

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Ενημερωμένοι:  May 21, 2026 ID: 000237298

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Ενημερωμένοι:  May 21, 2026 ID: 000233949

The article describes how to troubleshoot network connectivity issues for network cards.
Ενημερωμένοι:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Ενημερωμένοι:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Ενημερωμένοι:  May 21, 2026 ID: 000227912

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Ενημερωμένοι:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Ενημερωμένοι:  May 21, 2026 ID: 000227068

Dell Intel SATA SSD drives may report a not correctly functioning PDR3 event, potentially resulting in a drive failure condition.
Ενημερωμένοι:  May 21, 2026 ID: 000226989

This article describes how to view and clear the system event log (SEL) in System Setup.
Ενημερωμένοι:  May 21, 2026 ID: 000226396

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Ενημερωμένοι:  May 20, 2026 ID: 000224458

Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Ενημερωμένοι:  May 20, 2026 ID: 000223671

PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Ενημερωμένοι:  May 20, 2026 ID: 000223479

VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Ενημερωμένοι:  May 20, 2026 ID: 000223404