To ensure optimal performance and stability for your Dell system, be aware of the latest updates available for the drivers and firmware. There are several systems to do this as explained in the article below.
Ενημερωμένοι: January 08, 2026
ID: 000127716
This article provides information about the LIC008 error seen when importing the IDRAC License.
Ενημερωμένοι: December 09, 2025
ID: 000353269
This article describes how to install RACADM on VMware ESXi and demonstrates how to change the iDRAC IP address using RACADM commands.
Ενημερωμένοι: January 15, 2026
ID: 000193731
PowerEdge XE9780 server may not power on if multiple fans are missing.
Ενημερωμένοι: January 14, 2026
ID: 000413009
In some situations Dell Technical Support may request evidence to perform a more assertive diagnosis, this article illustrates how to attach files to your service request through the Dell support portal.
Ενημερωμένοι: January 13, 2026
ID: 000194683
High SMART error rates on some Enterprise hard drive are informational and have no bearing on hardware health.
Ενημερωμένοι: January 12, 2026
ID: 000147878
Learn how to create a bootable USB with Rufus to update Dell PowerEdge servers. Follow the step-by-step instructions to prepare and create a bootable USB media.
Ενημερωμένοι: January 12, 2026
ID: 000141551
This article provides an explanation of the backplane hard drive LED indicators.
Ενημερωμένοι: January 09, 2026
ID: 000413096
This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Ενημερωμένοι: January 09, 2026
ID: 000143247
PowerEdge systems may not always log downgraded PCIe links in LifeCycle (LC) or system event logs (SEL).
Ενημερωμένοι: January 09, 2026
ID: 000412311
If ESXi hosts use Trusted Platform Module (TPM), this article provides steps when the ESXi host is still accessible over SSH before any hardware changes.
Ενημερωμένοι: January 08, 2026
ID: 000318876
This article provides information about the VLT0204 error code and guidance.
Ενημερωμένοι: January 08, 2026
ID: 000403266
This article provides information about how to boot past the Driver Health Manager Screen.
Ενημερωμένοι: December 23, 2025
ID: 000148089
It’s a common misconception that if a PowerEdge server fails to boot, doesn’t complete POST, or experiences other issues, the iDRAC will also be inaccessible. In reality, iDRAC is often still online and available to assist with troubleshooting—even if it was never configured beforehand. Leveraging iDRAC to review recent events, analyze logs, and collect a SupportAssist Collection (TSR) is critical for accelerating diagnosis and recovery.
Ενημερωμένοι: December 15, 2025
ID: 000401536
Storage components may not be displayed, or the status may appear as Unknown after upgrading iDRAC9 firmware to version 7.20.60.50 or 7.20.70.50.
Ενημερωμένοι: December 12, 2025
ID: 000388426
Downstream Port Containment event may show up in the life cycle log and kernel logs when hot removing NVMe drives from a PowerEdge XE9780/XE9785.
Ενημερωμένοι: December 10, 2025
ID: 000375913
This article explains what a predictive drive failure (error code PDR16) means, why it occurs, and provides step-by-step instructions to troubleshoot and resolve the issue. It covers recommended actions such as backing up data, updating firmware, and replacing the disk if necessary to ensure storage health and prevent data loss.
Ενημερωμένοι: December 09, 2025
ID: 000126418
This article provides the recommended steps to help troubleshoot memory-related events on Dell PowerEdge servers.
Ενημερωμένοι: December 08, 2025
ID: 000304931
Guidance on how to use the iDRAC Direct feature on the PowerEdge XE9780 system.
Ενημερωμένοι: December 06, 2025
ID: 000372782
This article explains how to use iDRAC Direct to manage your PowerEdge server.
Ενημερωμένοι: December 04, 2025
ID: 000130077
Understand and troubleshoot PowerEdge hard disk drives, RAID, PowerEdge RAID Controller, and other storage hardware such as cables, backplane, so forth.
Ενημερωμένοι: December 03, 2025
ID: 000110444
This page explains the difference between drivers and firmware and how to update them on Dell PowerEdge Servers using different methods.
Ενημερωμένοι: December 02, 2025
ID: 000128194
This article explains how to create a Virtual Disk using the System Settings menu.
Ενημερωμένοι: December 01, 2025
ID: 000178269
This article provides links to download Dell trial 30 and 90-day evaluation license collection including iDRAC Enterprise, iDRAC Datacenter, Chassis Management Consoles (CMC) Enterprise, OpenManage Enterprise, and OpenManage Integration.
Ενημερωμένοι: November 25, 2025
ID: 000176472
This article provides general information about how to view and monitor server health from the IDRAC10 web interface.
Ενημερωμένοι: November 21, 2025
ID: 000394350
This article provides information about how to troubleshoot PCIe devices that are not being detected correctly.
Ενημερωμένοι: November 19, 2025
ID: 000300035
Hardware Diagnostics are embedded tools installed in the pre-OPERATING SYSTEM of your server to check hardware is working as designed.
Ενημερωμένοι: November 19, 2025
ID: 000132726
This article describes how to gather the necessary log files to troubleshoot a vSphere Tanzu issue.
Ενημερωμένοι: November 12, 2025
ID: 000187022
When running the nvidia-smi command, you may encounter a driver error stating that "nvidia-smi has failed because it could not communicate with the NVIDIA driver.
Ενημερωμένοι: November 08, 2025
ID: 000252982
This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Ενημερωμένοι: November 05, 2025
ID: 000136481