Είδη
Μη έγκυρη καταχώριση. Χρησιμοποιήστε μόνο γράμματα, αριθμούς και τυχόν ειδικούς χαρακτήρες εκτός από <>)(%/;,=#-/*
30 από 32 εμφανίζονται
32 από 32 εμφανίζονται
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
Ενημερωμένοι: March 31, 2026
ID: 000333712
This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server.
It is also relevant for 100% fan speeds.
Ενημερωμένοι: February 27, 2026
ID: 000227912
This KB is to provide information about Dell customized VMware ESXi support stance on the Dell 17th generation of PowerEdge servers. The 17th generation of PowerEdge servers is based on Intel® Xeon® 6500P/6700P (Granite Rapids SP) and AMD EPYC™ 9005 Series Processor (Turin).
Ενημερωμένοι: March 24, 2026
ID: 000334057
Dell PowerEdge 17G servers record inaccurate CPU index within iDRAC10 life cycle Log (LCLOG) and System event log (SEL) when machine check event (MCE) is recorded.
Ενημερωμένοι: March 18, 2026
ID: 000382576
Dell PowerEdge 17G Intel servers may record memory module temperature warning events in the Lifecycle Log and System Event Log during the server cold boot sequence.
Ενημερωμένοι: March 18, 2026
ID: 000381690
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Ενημερωμένοι: March 18, 2026
ID: 000333265
Dell iDRAC9 and iDRAC10 remediations are available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Ενημερωμένοι: March 17, 2026
ID: 000434533
Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Ενημερωμένοι: March 17, 2026
ID: 000368482
This knowledge base article offers a detailed guide for troubleshooting Trusted Platform Module (TPM) 2.0, Secure Boot, and ESXi-related issues on Dell servers. It provides step-by-step instructions to address common problems, ensuring the proper functioning and security of your server.
Ενημερωμένοι: February 27, 2026
ID: 000218542
Kioxia CM6 NVMe SSDs on 17‑generation servers experience I2C (Inter‑Integrated Circuit) communication issues. The fan speed stays locked at 100 % after OS boot. This behavior is observed on 17G servers only running Integrated Dell Remote Access Controller (iDRAC) 10 firmware version 1.20.80.51 or older.
Ενημερωμένοι: February 27, 2026
ID: 000430558
This article explains how to assign an Initial Company Administrator.
Ενημερωμένοι: February 23, 2026
ID: 000374134
PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Ενημερωμένοι: February 19, 2026
ID: 000415896
Dell PowerEdge 17G servers added MEMHOT error monitoring in iDRAC10 firmware version 1.20.80.50 combined with supported Field-Programmable Gate Array (FPGA) firmware. Servers configured with Power Supply Cold Redundancy feature enabled can record random SYS565 memory temperature warning events.
Ενημερωμένοι: February 19, 2026
ID: 000388703
This article explains how to promote Company Administrators.
Ενημερωμένοι: February 18, 2026
ID: 000374126
This article explains Dell guidelines on company administrator assignment.
Ενημερωμένοι: February 17, 2026
ID: 000379388
This article explains how to use iDRAC Direct to manage your PowerEdge server.
Ενημερωμένοι: January 22, 2026
ID: 000130077
It is a common misconception that if a PowerEdge server fails to boot, does not complete POST, or experiences other issues, the iDRAC will also be inaccessible. In reality, iDRAC is often still online and available to assist with troubleshooting—even if it was never configured beforehand. Leveraging iDRAC to review recent events, analyze logs, and collect a SupportAssist Collection (TSR) is critical for accelerating diagnosis and recovery.
Ενημερωμένοι: January 22, 2026
ID: 000401536
This article provides instructions on how the customer can gather their recovery key from their Trusted Platform Module (TPM) enabled host. The customer should keep the recovery key from each of their hosts in a safe place. Hardware replacement activities, such as system board replacements, require the recovery key for a smooth process.
Ενημερωμένοι: December 29, 2025
ID: 000220136
During cluster turn on of vSAN ready nodes, the vSAN network list does not exist. This causes the virtual machine (VM) status to be invalid.
Ενημερωμένοι: November 07, 2025
ID: 000297877
Dell iDRAC9 and iDRAC10 remediations are available for an arbitrary file export vulnerability that could be exploited by malicious users to compromise the affected system.
Ενημερωμένοι: November 06, 2025
ID: 000384516
Several requests regarding custom ISOs for the latest VMware patch releases for ESXi 7.0 and ESXi 8.0 have been received. The new VMware patch includes critical security updates for vulnerabilities CVE-2025-22224, CVE-2025-22225, and CVE-2025-22226. VMSA-2025-0004 is the official Broadcom article number which is commonly use to explain the issue to Tech Support.
Ενημερωμένοι: August 06, 2025
ID: 000291363
When a PS1010 or PS1030 NVMe SSD is installed, a PSOD may occur during production or gathering Operating System (OS) logs.
Ενημερωμένοι: August 05, 2025
ID: 000228837
On a Dell vSAN Original Storage Architecture (OSA) cluster with deduplication enabled, there are occurrences of drive faults reported on the NVMe devices. The vSAN OSA cluster is configured with NVMe devices as cache tier and SAS as capacity tiers. The drive faults are incorrectly reported on NVMe drives which are configured as cache tiers for the vSAN OSA cluster even though the failure is on the SAS drives participating in capacity tier.
Ενημερωμένοι: July 25, 2025
ID: 000348652
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Ενημερωμένοι: July 10, 2025
ID: 000256907
This article explains how to update the BIOS version of a Dell PowerEdge Server using EFI file. The update can be done directly from the Unified Extensible Firmware Interface (UEFI) interface.
Ενημερωμένοι: June 18, 2025
ID: 000142454
Users may request a drive be replaced due to I/O errors or if the drive is marked as "failed" or "unusable" by Software-Defined-Storage (SDS) solution.
Ενημερωμένοι: June 17, 2025
ID: 000219050
Dell SAS SSD models SS530 and SS540, when used as a VMware vSAN cache tier, show accelerated write endurance loss.
Ενημερωμένοι: May 08, 2025
ID: 000218401
The following document shows how to import a Dell VSAN catalog into Dell Repository Manager (DRM), using CLI in a Linux environment. The resulting export can be used with Dell EMC OpenManage Integration for VMware vCenter (OMIVV) and OpenManage Enteprise Virtual vCenter plug-in (OMEVV).
Ενημερωμένοι: April 09, 2025
ID: 000204239
This article describes how to find the iDRAC's current MAC address.
Ενημερωμένοι: December 17, 2024
ID: 000226214
This article describes how to view and clear the system event log (SEL) in System Setup.
Ενημερωμένοι: December 17, 2024
ID: 000226396