Skip to main content

VxFlex Ready Node R640

VxFlex Ready Node R640

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 251 shown
251 out of 251 shown

Learn how to create and export a SupportAssist Collection using iDRAC9 and iDRAC10 on Dell devices. Resolve technical issues with this step-by-step guide.
Updated:  May 11, 2026 ID: 000126308

Dell has a Customer Replaceable Unit (CRU) program for many of our hardware systems. The CRU program allows customers to replace designated hardware components. For a list of the hardware components that are designated as CRU for a specific hardware system, go to the Dell Warranty and Maintenance Page.
Updated:  May 10, 2026 ID: 000187496

Disk devices attached or configured to SVM or SDS nodes are missing Serial Number information and are not listed in the /dev/disk/by-id directory.
Updated:  May 11, 2026 ID: 000225903

Unable to upgrade the Switch OS using PFxM.
Updated:  May 11, 2026 ID: 000222614

Unable to complete the add existing resource group wizard for a PowerFlex MDS system.
Updated:  May 11, 2026 ID: 000226694

The 4.x PFxM UI is not loading because the PowerFlex Management Platform "PFMP" pod SDNAS gateway is not in a healthy state.
Updated:  May 11, 2026 ID: 000220000

The UI shows a UNABLE_TO_RECEIVE_MDM_EVENTS alert because the manager cannot reach the ActiveMQ broker on port 61714; the broker is blocked or the service is down, so MDM events are not displayed.
Updated:  May 11, 2026 ID: 000221796

Memory errors and CMCI storm entries in logs cause load, SDS stalls and decoupling; a failing Dual In-line memory module (DIMM) triggers interrupts, EDAC CMCI rate exceeds threshold, causing storm.
Updated:  May 11, 2026 ID: 000197735

After ESXi patches, hosts with Mellanox ConnectX‑4 5 NICs may encounter purple screen crashes when the nmlx5_rdma (or nmlx4_rdma) driver loads, because PowerFlex relies solely on the nmlx5_core driver.
Updated:  May 10, 2026 ID: 000191458

Using PowerFlex Management Portal (PFMP), capture a group’s network mappings, service details, credentials and node IPs, remove the group (non‑delete), then re‑add it with the recorded information.
Updated:  May 10, 2026 ID: 000237096

Dial home alert is logged when there is a disconnection between SDC multiple SDS.
Updated:  May 09, 2026 ID: 000185174

This article explains how to use iDRAC Direct to manage your PowerEdge server.
Updated:  May 09, 2026 ID: 000130077

This article explains how to use the internal HTTP share for 4.x PowerFlex Manager Release Certification Matrix (RCM), Intelligent Catalog (IC), ISO uploads.
Updated:  May 08, 2026 ID: 000220681

This Article explains the details of an MDM cluster in a PowerFlex solution.
Updated:  May 08, 2026 ID: 000249312

Slow, non‑SSD storage on the cluster VMs leads to etcd latency over one second, triggering repeated pod restarts, node NotReady states and loss of PowerFlex Management Platform (PFMP) UI access.
Updated:  May 08, 2026 ID: 000222971

Offline upgrade of PowerFlex Manager How to manually upgrade PowerFlex Manager without Secure Remote Services.
Updated:  May 08, 2026 ID: 000183041

Collecting get_info logs from Gateways Fails with Error: The logs file in node x.x.x.x was not found running command.LogCollectionCommand.
Updated:  May 08, 2026 ID: 000182487

Details the graceful reboot of PowerFlex Management Platform (PFMP) VMs for version 4.X, including labeling, draining, and rebooting MVMs while keeping two nodes active and checking PostgreSQL health. In the scope of this procedure, MVM1 is the postgres Leader. It is drained and rebooted last.
Updated:  May 07, 2026 ID: 000225550

This article provides links to documentation for PowerFlex Rack, PowerFlex Appliance, PowerFlex Custom Node, VxFlex Ready Node, PowerFlex Software, PowerFlex for AWS, PowerFlex for Azure and CloudLink.
Updated:  May 07, 2026 ID: 000308007

The user reported that the Power Supply Unit (PSU) has encountered issues when inserted into the server. It failed to power on the Dell PowerEdge R640 server, but the indicator on the PSU shows a green LED. Checking the TSR log finds the messages "PSU redundancy lost" or "The system board XXX voltage is out of range."
Updated:  May 07, 2026 ID: 000215889

Connectivity issues may be seen with either the Gateway or the Presentation server with "port out of range" or "Trying to reconnect."
Updated:  May 07, 2026 ID: 000198913

This article provides information about Dell Boot Optimized Storage Solution (BOSS) PCIe cards. It also provides instructions for installing Windows, Red Hat, SuSE, Ubuntu, and related Linux distributions onto these cards.
Updated:  May 06, 2026 ID: 000177584

Domain Name System (DNS) resolving the local hostname may return the internal IP address of the USB Network Interface Card (NIC) passthrough device enabled by iDRAC Service Module (iSM). This can cause issues with internal network devices configured with 169.254.x.x nonroutable addresses. The metric of the USB NIC device should be manually set to a high number so that internal network devices take precedence.
Updated:  May 06, 2026 ID: 000177295

This article outlines how to create a firmware baseline, view compliance reports, and apply updates in Dell OpenManage Enterprise.
Updated:  May 05, 2026 ID: 000144728

This article is about an error that a user may see when adding a "DAX" device into the acceleration Pool.
Updated:  May 05, 2026 ID: 000168245

This article explains the steps to reset the PowerFlex Manager Platform (PFMP) admin password, or any account in the PFMP.
Updated:  May 04, 2026 ID: 000247978

A workaround for when the BIOS update fails for the first time on 14G PowerEdge servers.
Updated:  May 02, 2026 ID: 000144961

This article explains how to update the BIOS version of a Dell PowerEdge Server using EFI file. The update can be done directly from the Unified Extensible Firmware Interface (UEFI) interface.
Updated:  May 01, 2026 ID: 000142454

The Dell Nautilus Firmware Update Utility is flexible and simple to use as it contains all the latest, relevant firmware updates for hard drives in your Dell server.
Updated:  May 01, 2026 ID: 000141811

iDRAC update available to resolve this fan problem seen on some PowerEdge servers.
Updated:  May 01, 2026 ID: 000140533