Skip to main content

Dell Server 9712a

Dell Server 9712a

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 194 shown
194 out of 194 shown

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  May 25, 2026 ID: 000136481

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

PowerEdge systems may not always log downgraded PCIe links in LifeCycle (LC) or system event logs (SEL).
Updated:  May 24, 2026 ID: 000412311

Micron 9550 E1.S solid state drives (Dell part numbers HRF8G, 2G1RR) can fail a short Device Self‑Test (DST) if the DST log (Log ID 0x06) is read within 2 seconds of start due to a bad pointer.
Updated:  May 24, 2026 ID: 000391814

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Updated:  May 24, 2026 ID: 000379421

Dell Micron 7450 and 7500 Non-Volatile Memory Express solid state drives may encounter drive initialization failure due to a firmware issue, resulting in the solid state drives being unrecoverable.
Updated:  May 23, 2026 ID: 000368482

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Using the Linux command "lspci -vvv" on PowerEdge XE9685L, the "LnkSta" value of the NVIDIA ConnectX-7 device is shown as "downgraded."
Updated:  May 22, 2026 ID: 000308325

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

This article describes how to view and clear the system event log (SEL) in System Setup.
Updated:  May 21, 2026 ID: 000226396

This article describes how to find the iDRAC's current MAC address.
Updated:  May 21, 2026 ID: 000226214

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Updated:  May 20, 2026 ID: 000224458

This document describes the objects and equipment used by Customer Engineers (CEs) when on-site. Please check and prepare in advance.
Updated:  May 20, 2026 ID: 000224128

In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Updated:  May 19, 2026 ID: 000221490

When in a SNAPI enabled configuration, the Dell Mellanox Ethernet and InfiniBand NICs may display 0000:0000:0000:0000 as the virtual node GUID for the second partition.
Updated:  May 19, 2026 ID: 000221406

Firmware upgrades to Broadcom network devices may fail with a "libpci.so: Cannot open" error when run from a Smart Bootable ISO image created with Dell Repository Manager 3.x.
Updated:  May 19, 2026 ID: 000221180

This article provides three methods to confirm the SSD Piece Part Identification (PPID)
Updated:  May 19, 2026 ID: 000466928

When creating a Power Control job from OpenManage Enterprise and the following wizard options are selected Power Options: Power Cycle and 'Shutdown OS First' box is checked results in the target host systems being ForceReset.
Updated:  May 19, 2026 ID: 000218293

Troubleshooting steps for the VMware vCenter unable to register to Dell OpenManage Enterprise plug-in for VMware vCenter (OMEVV) because another instance is already registered.
Updated:  May 17, 2026 ID: 000213179

OpenManage Enterprise (OME) Services plug-in may not show a device, or the device is in staging status.
Updated:  May 17, 2026 ID: 000213172

Dell License Manager 1.7 dose not work with 16G APOS SKU
Updated:  May 17, 2026 ID: 000212740

This article covers the process of collecting debug logs from OpenManage Enterprise 3.9 and later.
Updated:  May 17, 2026 ID: 000212597

Dell System Update (DSU) 2.0.0 for VMware ESXi fails with "Inventory file not found" error if the "--use-idrac-passthrough" option is not specified at launch.
Updated:  May 16, 2026 ID: 000205742

Do Not Update iDRAC FW to 5.10.50.00 or later on PowerEdge server with RCI qualified Broadcom 57504 (DPN: 5187Y) that has old FW 216.x.xx.x.
Updated:  May 15, 2026 ID: 000204894

The firmware of PowerEdge server hard drives is a critical component in the server system. Regularly updating and maintaining this firmware is essential for server performance, security, and compatibility. Hard drive firmware updates can often fix known hardware faults and issues, address identified vulnerabilities and security problems, and potentially introduce new features, improvements, and enhancements.
Updated:  May 15, 2026 ID: 000455478

The VM does not turn on after configuring PCI Device passthrough on the ESXi host and adding the device to the VM. It gets stuck at 80% and then results in an error "total number of pages needed (4206594) exceeds the limit (917504)."
Updated:  May 14, 2026 ID: 000199172

This article provides links to download Dell trial 30 and 90-day evaluation license collection including iDRAC Enterprise, iDRAC Datacenter, Chassis Management Consoles (CMC) Enterprise, OpenManage Enterprise, and OpenManage Integration.
Updated:  May 13, 2026 ID: 000176472