Articles
Tooltip title
Select a category and then related component(s) to find articles about specific hardware and software.
Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*
30 out of 311 shown
311 out of 311 shown
This article lists the PowerEdge RAID Controllers (PERC) by series family (generation) for Dell systems. There are several types of PERC controllers available depending on internal or external storage connectors, maximum drive support, and RAID support.
Updated: August 07, 2026
ID: 000131648
This article details the most recent firmware version for Integrated Dell Remote Access Controller 10 (iDRAC10), designed for Dell PowerEdge servers from the 17th generation onwards.
Updated: July 08, 2026
ID: 000305325
Central Processing Unit (CPU) throttles to base frequency ~600 MHz in Cold Redundancy, temperature is normal; a LiteON Power Supply Unit (PSU) firmware issues an OCW‑related SMB alert, triggering a policy limiting CPU power.
Updated: August 14, 2026
ID: 000486739
The firmware of PowerEdge server hard drives is a critical component in the server system. Regularly updating and maintaining this firmware is essential for server performance, security, and compatibility.
Hard drive firmware updates can often fix known hardware faults and issues, address identified vulnerabilities and security problems, and potentially introduce new features, improvements, and enhancements.
Updated: August 13, 2026
ID: 000226155
Dell PowerEdge Server remediation is available for 2026.2 Intel Platform Update (IPU) components that could be exploited by malicious users to compromise the affected systems.
Updated: August 11, 2026
ID: 000498351
Dell PowerEdge Server remediation is available for a vulnerability in OOB-MSM module in Intel® Xeon® 6 processor with Intel® TDX that could be exploited by malicious users to compromise the affected systems.
Updated: August 11, 2026
ID: 000498346
This article lists the steps to enable 40 Gbps Link speeds on DELL OEM version of Broadcom 57508 Network Adapters. It also lists the compatible DELL Optics that support 40 Gbps link speeds.
Updated: August 10, 2026
ID: 000455857
Dell iDRAC9 and iDRAC10 remediations for an sqlite security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated: August 10, 2026
ID: 000497919
Dell iDRAC10 remediation for an avahi security vulnerability that could be exploited by malicious users to compromise the affected system.
Updated: August 10, 2026
ID: 000497884
Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Updated: August 10, 2026
ID: 000222201
Micron 5x00 Series SSDs may experience read/write performance degradation after reaching approximately 65,535 power-on hours (POH) (~7.5 years of continuous operation).
This issue is limited to performance impact only and does not cause data loss or drive failure.
Updated: August 07, 2026
ID: 000464492
This KB article contains a How to Video that covers how to Install OpenManage Server Administrator (OMSA) on a Windows Server.
Updated: July 30, 2026
ID: 000185559
On systems equipped with NVIDIA A100 or H200 NVL GPUs running NVIDIA Driver, the NVRM message "NVRM: gpuClearFbhubPoisonIntrForBug2924523_GA100: FBHUB Interrupt detected. Clearing it." may be observed in the Linux kernel log such as dmesg.
Updated: July 30, 2026
ID: 000491664
Upon generating TSR on 17G servers, certain server details may be missing from the TSR viewer html file
Updated: July 22, 2026
ID: 000489951
Dell PowerEdge Server remediation is available for OpenSSL Vulnerabilities that could be exploited by malicious users to compromise the affected systems.
Updated: July 14, 2026
ID: 000489258
This article outlines the actions required to prepare a system for retirement or repurposing using the LifeCycle controller.
Updated: July 14, 2026
ID: 000198190
Dell PM1735a Non-Volatile Memory Express (NVMe) drive failing in PowerEdge servers.
Updated: July 10, 2026
ID: 000481601
Information about servicing and troubleshooting issues in your Dell PowerEdge Rack and Tower servers' hardware and System Management tools
Updated: July 10, 2026
ID: 000203864
In Linux, NVMe drives connected behind a PowerEdge RAID Controller (PERC) may exhibit lower performance than expected during small I/O workload testing.
This occurs because the OS identifies these drives as standard SCSI block devices (/dev/sdX) rather than native NVMe devices (/dev/nvmeXnX). This identity leads to the application of suboptimal default I/O schedulers.
Updated: July 09, 2026
ID: 000443257
This article explains how to address the error "The system has found a problem on your machine and cannot continue. Unable to restore the system configuration. A security violation was detected". Purple screen / Purple screen of Death (PSOD)
Updated: July 06, 2026
ID: 000436068
Best Practices for Dell PowerEdge Server Power Supplies and UPSs
Updated: July 03, 2026
ID: 000484919
This article explains the requirements to deploy VMware ESXi 9 virtual machines with 4Kn end‑to‑end (E2E) storage when using Dell PowerEdge PERC12 (H965) and newer controllers. It also covers how to identify when ESXi is using 4Kn software emulation (SWE) instead of true 4Kn E2E, and what conditions prevent E2E.
Updated: July 03, 2026
ID: 000467282
Samsung PM9D3a and PM9D5a NVMe SSDs used in PowerEdge servers lack support for the Security Protocol and Data Model (SPDM), causing SPDM‑related features to fail.
Updated: July 02, 2026
ID: 000459691
This article explains Dell’s 17th Generation (17G) transition from Dell‑custom Ethernet network interface cards (NICs) to industry‑standard NICs, detailing how this change aligns with industry practices while preserving Dell validation, life cycle management, and enterprise support, with standardized iDRAC‑based management.
Updated: July 02, 2026
ID: 000449389
Understanding Cold Redundancy: Feature Overview and Comparisons with Hot Spare and Redundancy Policies
Updated: July 02, 2026
ID: 000447877
Dell Technologies guidance to mitigate risk and resolution for the side-channel analysis vulnerabilities (also known as Meltdown and Spectre) for servers, storage, and networking products. For specific information about affected platforms and next steps to apply the updates, see this guide.
Updated: July 02, 2026
ID: 000178106
Dell EMC guidance to mitigate risk and resolution for the side-channel analysis vulnerabilities (also known as Speculative Store Bypass and Rogue System Register Read) servers, storage and networking products. For specific information on affected platforms and next steps to apply the updates, please refer to this guide.
Updated: July 01, 2026
ID: 000178082
Kioxia CM6 NVMe SSDs on 17‑generation servers experience I2C (Inter‑Integrated Circuit) communication issues. The fan speed stays locked at 100 % after OS boot. This behavior is observed on 17G servers only running Integrated Dell Remote Access Controller (iDRAC) 10 firmware version 1.30.10.50 or older.
Updated: July 01, 2026
ID: 000430558
Learn how to set up a Dell PowerEdge server by configuring iDRAC, launching the Lifecycle Controller, updating firmware, and installing a supported OS.
Updated: June 29, 2026
ID: 000123958
Dell iDRAC10 remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated: June 25, 2026
ID: 000481646