This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Datacenter Infrastructure products. We carefully evaluate and monitor code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated: February 09, 2026
ID: 000205512
This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
Updated: February 07, 2026
ID: 000127944
This article contains instructions for migrating a VMware vStorage VMFS datastore from SDC to NVMe over TCP using Storage vMotion.
Updated: February 13, 2026
ID: 000337908
This article explains step by step how to do an NVMe device replacement and do the RDM config in the SVM to be correctly mapped to the ESXi host
Updated: February 13, 2026
ID: 000334185
This article provides information about how to import a foreign configuration RAID array on the system setup (F2) menu.
Updated: February 13, 2026
ID: 000122457
Since the introduction of Clustered VMDK on VMFS datastores, applications like Windows Server Failover Cluster (WSFC) no longer require Raw Device Mappings (RDMs) to use SCSI‑3 persistent reservations (SCSI3‑PR). Because of this, Broadcom does not offer RDM support for the NVMeoF protocol. Customers using RDMs with the SDC who want to move to NVMe/TCP must convert those disks to VMDKs on a VMFS datastore with the Clustered VMDK property. This conversion cannot be done with Storage vMotion, so applications such as WSFC will incur downtime.
This KB explains how to perform the WSFC conversion at a high-level. It also covers converting an Oracle RAC environment from RDMs to shared VMDKs on NVMe/TCP, even though Oracle RAC does not require SCSI3‑PR. Oracle RAC can run on an SDC‑based VMFS datastore, but because PowerFlex does not support Clustered VMDK on SDC‑based VMFS, SCSI3‑PR‑dependent applications cannot use that configuration. Oracle RAC explanations are also high-level.
Updated: February 12, 2026
ID: 000417124
PowerFlex Upgrade Customer Preparation Guide
Updated: February 12, 2026
ID: 000340894
CloudLink How to Configure Active Directory for the CloudLink encryption keystore
Updated: February 11, 2026
ID: 000273274
The RestAPI call to switch MDM ownership through the Gateway fails with a timeout.
Updated: February 11, 2026
ID: 000196837
PowerFlex allows authentication and authorization to be enabled for all SDCs connected to a cluster. Once authentication and authorization are enabled, older SDC clients and SDCs without a configured password are disconnected.
Updated: February 09, 2026
ID: 000332124
Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Updated: February 09, 2026
ID: 000185734
Running command svm status connection is showing both CloudLink nodes as Inaccessible due to blocked port UDP 1194.
Updated: February 09, 2026
ID: 000384973
In the PFxM UI, there is an alert stating that events from the MDM are not being retrieved.
Updated: February 09, 2026
ID: 000221796
Upgrading to PowerFlex Management Platform (PFMP) 4.8 may cause the UI to load with the error "Failed to initialize" or be accessible but unstable.
Updated: February 09, 2026
ID: 000417603
PowerFlex Manager cannot interact with the PowerFlex system when a login banner is configured, disrupting automation tasks.
Updated: February 07, 2026
ID: 000253256
RKE2 Certificates should be renewed automatically but in rare cases, this renewal does not happen.
This procedure covers how to Rotate RKE2 Certificates on MVM Nodes.
Updated: February 06, 2026
ID: 000325517
PowerFlex Gateway (GW) upgrade fails when upgrading to version 4.6.2.
Updated: February 06, 2026
ID: 000311733
During replication initial copy the size of the volume transfer might report x5-10 times higher than the actual volume size.
Updated: February 06, 2026
ID: 000261389
During Network Device Upgrade (NDU) with a very short upload timeout]
Updated: February 06, 2026
ID: 000225471
This article provides a resolution when remote access for the ESXi local user account root is locked for 900 s after failed login attempts. Connect to the iDRAC console to access the ESXi shell then run the reset command.
Updated: February 05, 2026
ID: 000071365
When performing many tasks related to CloudLink Agent on Linux machines, you use the SVM command. This command has several subcommands that are used to perform actions including registering, encrypting, reloading machines, and removing mount points.
Updated: February 05, 2026
ID: 000421572
The upgrade fails when SupportAssist is configured before running the upgrade for version 4.6.2.
Updated: February 04, 2026
ID: 000311707
Unable to unmap volumes from the SDC. "Error: MDM failed command. Status: The volume class provided does not match the expected volume class"
Updated: February 04, 2026
ID: 000421825
This article explains how to split a large Resource Group (RG) into smaller RGs while using the same Protection Domain (PD) in PowerFlex Management Platform (PFMP) or to split a large Service into smaller Services in PowerFlex Manager (PFxM).
Updated: February 04, 2026
ID: 000388444
For security reasons it might be necessary to change the password for the root user on a VMware ESXi host after installation. This article provides guidance to change the root password for the VMware ESXi host using VMware vSphere Client, VMware ESXi shell command, and VMware ESXi host System Customization menu.
Updated: February 04, 2026
ID: 000324321
PowerFlex/PowerEdge: How to Sanitize NVDIMM - Video
Updated: February 03, 2026
ID: 000221219
this article explains a rare occurrence if a bug were After Upgrade OS packages on MVMs still show old version and how to fix it
Updated: February 03, 2026
ID: 000423205
This article provides links to PowerFlex software technical documentation.
Updated: February 03, 2026
ID: 000314729
When PowerPath for Windows version 6.1 is installed on Windows Server 2016, validation alerts indicate that many drivers have dates earlier than the OS, because the PowerPath release predates the OS.
Updated: February 03, 2026
ID: 000062991
This article explains how to Standardizing Data VLAN Tagging After PFxM Upgrade and OS Conversion.
Updated: February 03, 2026
ID: 000406776