VxRail cannot collect the ESXi log bundle when vSAN encryption is enabled.
Updated: May 15, 2026
ID: 000202507
Failed to add 13G node at 4.7.x version into the VxRail 7.0.400 cluster, if the cluster was upgraded from 7.0.210 or above version to 7.0.400.
Updated: May 15, 2026
ID: 000202264
Dell VxRail: Secure Remote Services (SRS) and Secure Connect Gateway (SCG) Support Matrix.
Updated: May 15, 2026
ID: 000203513
Trying to add nodes using the VxRM plugin completes all the steps in the wizard including the Validation step. After clicking Finish, the plugin loads for some time and then fails due to incorrect entries in the resolv.conf file.
Updated: May 15, 2026
ID: 000200340
This article details how to find one or more part numbers and type of a VxRail node's SFP transceivers. It can help with determining whether the attached network cables are Direct Attach Copper (DAC). The article provides examples of how to find the information during a live support session or within logs.
Updated: May 15, 2026
ID: 000202677
Lifecycle Management (LCM) failed with "Unable to Get Local Issuer Certificate" When Update VC Cert.
Updated: May 15, 2026
ID: 000202407
This article helps resolve the issue when a two node VxRail cluster deployment fails at 77% with the error message "Failed to apply vm VxRail Manager storage policy."
Updated: May 15, 2026
ID: 000202375
This article outlines the response from VxRail Engineering to the security issues described in CVE-2022-22963/CVE-2022-22965 and recommendations to fix the issues.
Updated: May 13, 2026
ID: 000198333
Event code: MYSTIC034010
This event code indicates: 'Failed to delete device from ESRS VE'
Updated: May 13, 2026
ID: 000042751
Event code: VXR500AMP0301
This event code indicates "The system board <name> current is less than the lower critical threshold."
Updated: May 13, 2026
ID: 000013639
Event code: VXR500AMP0313
This event code indicates "System level current is less than the lower critical threshold."
Updated: May 13, 2026
ID: 000013615
Event code: VXR500BAT0002
This event code indicates "The system board battery has failed."
Updated: May 13, 2026
ID: 000013613
Event code: VXR500BAT1029
This event code indicates "The battery on <controller name> can no longer recharge."
Updated: May 13, 2026
ID: 000013612
Event code: VXR500AMP0322
This event code indicates "Chassis power level current is outside of range."
Updated: May 13, 2026
ID: 000013611
Event code VXR500AMP0315
This event code indicates "System level current is greater than the upper critical threshold."
Updated: May 13, 2026
ID: 000013610
Event code: VXR500BAT0004
This event code indicates "The system board battery is absent."
Updated: May 13, 2026
ID: 000013609
Event code: VXR500BAT0007
This event code indicates "The storage battery has failed."
Updated: May 13, 2026
ID: 000013605
The VxVerify plug-in for ADC can leave the SSH service enabled on ESXi nodes.
Updated: May 13, 2026
ID: 000197998
Event code: VXR500PCI1350
This event code indicates "A PCI system error was detected on a component at slot <number>."
Updated: May 13, 2026
ID: 000013552
Event code: VXR500FAN1002
This event code indicates "<Fan Sensor Name> has failed."
Updated: May 13, 2026
ID: 000013550
Event code: VXR500PCI1306
This event code indicates "A software error was detected on a component at bus <bus> device <device> function <func>."
Updated: May 13, 2026
ID: 000013549
Event code: VXR500FAN0006
This event code indicates "Fan <number> is removed."
Updated: May 13, 2026
ID: 000013547
Event code: VXR500PCI1356
This event code indicates "A bus uncorrectable error was detected on a component at slot <number>."
Updated: May 13, 2026
ID: 000013546
Update job fails due to connectivity migration issue when upgrading VxRail to 7.0.350 or above.
Updated: May 13, 2026
ID: 000197594
Event code: VXR500PCI2002
This event code indicates "A fatal IO error detected on a component at slot <number>."
Updated: May 13, 2026
ID: 000013545
Event code: VXR500FAN0003
This event code indicates "Fan <number> RPM is greater than the upper critical threshold."
Updated: May 13, 2026
ID: 000013543
Event code: VXR500PCI1320
This event code indicates "A bus fatal error was detected on a component at bus <bus> device <device> function <func>."
Updated: May 13, 2026
ID: 000013542
Event code: VXR500CTL59
This event code indicates "<Controller name> SAS expander error: <args>"
Updated: May 13, 2026
ID: 000013541
Event code: VXR500PCI1358
This event code indicates "A fatal error was detected on a component at slot <number>."
Updated: May 13, 2026
ID: 000013539
Event code: VXR500PCI3006
This event code indicates "Failed to get Link Tuning or FlexAddress data from iDRAC."
Updated: May 13, 2026
ID: 000013538