Skip to main content
NetWorker image

NetWorker

NetWorker

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 2081 shown
2081 out of 2081 shown

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  August 31, 2026 ID: 000502480

This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Updated:  August 31, 2026 ID: 000205512

NetWorker VMware Protection (NVP) vProxy backups fail because the vProxy cannot lock the virtual machine at the start of the backup workflow. A previous backup operation left VM lock attributes in place after encountering a problem during execution. The stale lock prevents new backup operations from starting on the affected VM.
Updated:  September 04, 2026 ID: 000031523

NetWorker VMware Protection (NVP) vProxy backups fail with a "-500: Panic occurred: runtime error" when the /data01 partition on the vProxy appliance reaches 100% capacity. The /data01 partition stores backup session logs with a default retention of one month. When the partition is full, the vProxy cannot write session logs and the backup process panics.
Updated:  September 04, 2026 ID: 000033993

NetWorker VMware Protection (NVP) vProxy backups fail with "The VM backup request is not valid" after repeated retry attempts. The NetWorker server reports that the Data Domain (DD) has reached its maximum read stream count. The DD read stream exhaustion prevents new backup sessions from being established on the NetWorker storage node.
Updated:  September 04, 2026 ID: 000053641

The NetWorker Virtual Edition (NVE) installation fails at 50% when configuring the NetWorker Authentication Service. The Authc Admin Password contains an equal sign, which is not a valid special character for the NVE password complexity check. The installation cannot proceed and the NVE must be redeployed with a compliant password.
Updated:  September 04, 2026 ID: 000170284

NetWorker VMware Protection (NVP) vProxy backup actions complete successfully. However, the clone action fails with "no available devices to clone." The disk volumes in the target clone pool are not set to "Appendable" mode. Without this mode, the clone action cannot write to the volumes.
Updated:  September 04, 2026 ID: 000065191

A restore failed with error 11015, invalid VMDK filename; logs show cancelled browse tasks and failures, caused by a version mismatch between the Avamar proxy (19.7) and server.
Updated:  September 03, 2026 ID: 000203720

Dell Avamar, Dell Networker Virtual Edition (NVE) and Dell PowerProtect DP Series Appliance / Dell Integrated Data Protection Appliance (IDPA) remediation is available for multiple vulnerabilities that could be exploited by malicious users to compromise the affected system.
Updated:  September 03, 2026 ID: 000505510

This is a general overview of monitoring NetWorker Logs from Grafana
Updated:  September 03, 2026 ID: 000505277

Welcome to the Avamar Data Migration enabler (ADMe) landing page.
Updated:  September 03, 2026 ID: 000182609

This article details the steps required to access the NetWorker Management Console (NMC) after upgrading to 19.13 or later.
Updated:  September 03, 2026 ID: 000334281

This KB provides an alternative method for performing a VMware File Level Restore (FLR) which does not require an available vProxy appliance. This method can be used if the standard NetWorker VMware Protection (NVP) FLR process is failing, unsupported Virtual Machine's (VM) configuration, or Operating System. The steps outlined in this KB must be performed with the involvement of the NetWorker Backup Administrator, VM's System Administrator, and VMware Administrator.
Updated:  September 01, 2026 ID: 000224596

This article provides a general overview of how VMware Virtual Machine (VM) backup levels and sizes that are reported in NetWorker when using the NetWorker VMware Protection (NVP) solution.
Updated:  September 01, 2026 ID: 000197202

This article outlines how to collect vProxy support bundles, NetWorker logs for VMware Protection, and logs needed when a vProxy system crash occurs.
Updated:  September 01, 2026 ID: 000022831

Does NetWorker Virtual Edition (NVE) support Azure Zone-Redundant Storage (ZRS) for the NVE OS disk and data disks to provide cross-zone disk replication and recovery during an Azure Availability Zone failure?
Updated:  September 01, 2026 ID: 000504707

This KB is intended to aid backup administrators and support agents who are unfamiliar with the NetWorker VMware Protection (NVP) solution. It gives a general overview of vProxy components and logs, additional relevant articles are also provided. This KB can be used to perform initial diagnoses when engaging support to ensure that an accurate issue statement is provided.
Updated:  September 01, 2026 ID: 000022016

How to Install the NetWorker Management Web UI (NWUI) software.
Updated:  September 01, 2026 ID: 000008992

A VMware vCenter server is added to NetWorker using an AD account. The vCenter is integrated with Azure Entra ID and the account used within NetWorker is from Entra ID. NetWorker Authentication with the VMware vCenter fails, resulting in failed inventory processing and NetWorker VMware Protection (NVP) backups.
Updated:  August 31, 2026 ID: 000372981

The vProxy appliance is deployed with a static IPv4 address that never appears on the VM and does not respond; wickedd reports duplicate‑IP errors because the address is in use on the network.
Updated:  August 28, 2026 ID: 000499204

The NetWorker nsrimportclient process fails with a DNS resolution error when importing clients to a destination server.
Updated:  August 28, 2026 ID: 000379428

A FLR Mount fails with the error: "NFS has reached the maximum number of supported volumes" on Dell NVP vProxy.
Updated:  August 28, 2026 ID: 000180271

NetWorker Management Console 19.13.0.2 and later fails to install or upgrade on Windows system.
Updated:  August 27, 2026 ID: 000456525

NetWorker Server’s or Client’s service disruption in HA (High Availability) cluster nodes that are installed with Red Hat Enterprise Linux (RHEL) 8.2, 8.3, 8.4, and 8.6 operating system versions.
Updated:  August 27, 2026 ID: 000191542

After upgrading to Networker version 19.13.0.3, Recover Space operation for some volumes is ailing.
Updated:  August 26, 2026 ID: 000502664

The NetWorker command `nsrcapinfo` is used to collect information about backups performed on the NetWorker server. It is observed that it is reporting the provisioned size of VM backups.
Updated:  August 25, 2026 ID: 000228905

How to install Platform Security Rollup for NetWorker Virtual Edition (NVE) using Dell's Installation Manager. Follow our guide to secure and up-to-date NVE systems, covering preupgrade checks, installation procedures, and troubleshooting upgrade failures.
Updated:  August 25, 2026 ID: 000052627

NetWorker may incorrectly report LTO-7, LTO-8, and LTO-9 tape volumes as 100% utilized or full before their native capacity is reached. No "prematurely full" errors are observed in the daemon logs, and the issue does not affect actual tape usage, backup operations, cloning, or recoveries.
Updated:  August 21, 2026 ID: 000500889

A file-level restore (FLR) performed through the NetWorker VMware Protection (NVP) vProxy appliance fails while mounting virtual machine disk (VMDK) files on the target virtual machine with the error "Another task is already in progress." The FLR cleanup process also fails to remove the partially mounted VMDK files, which can prevent the VM from starting properly upon reboot. This issue occurs when the target VM is simultaneously protected by vSphere Replication Manager or another backup/replication product that holds a concurrent task on the VM.
Updated:  August 21, 2026 ID: 000196863

After upgrading to NetWorker 18.2.0.0, NetWorker VMware Protection (NVP) vProxies become unavailable, libCURL error 7 occurs because the vProxy registers on an interface than the server, mismatch.
Updated:  August 20, 2026 ID: 000168096