In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Naprakész: May 19, 2026
Azonosító: 000221490
The Dell HBA465e or HBA355e SAS host bus adapter (HBA) may be supplied as a drop in box (DIB) item alongside PowerEdge servers. This article provides direction on selecting an appropriate PCI-e slot.
Naprakész: May 19, 2026
Azonosító: 000220555
When Dell Intel E810-CQDA2 part number 85F8F or DWNRF is used with FR1 transceiver part number PJ62G, it cannot link up. The maximum power consumption of the transceiver Dell Part Number (DPN) PJ62G is 4W, which exceeds the NIC device's power supply limit of 3.5W.
Naprakész: May 21, 2026
Azonosító: 000224793
After successful installation of NVIDIA GPU driver on Red Hat Enterprise Linux 9.3, performing nvidia-smi operations may report "no devices found."
Naprakész: May 20, 2026
Azonosító: 000224586
Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Naprakész: May 20, 2026
Azonosító: 000224458
This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Naprakész: May 20, 2026
Azonosító: 000223832
PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Naprakész: May 20, 2026
Azonosító: 000223831
Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Naprakész: May 20, 2026
Azonosító: 000223671
PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Naprakész: May 20, 2026
Azonosító: 000223479
Dell PowerEdge server with a Broadcom BCM57414 PCIe adapter could encounter intermittent network-disconnected problem in a VMware NSX-T environment.
Naprakész: May 20, 2026
Azonosító: 000223469
Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Naprakész: May 20, 2026
Azonosító: 000223462
PowerEdge server intermittently encounters a UEFI iSCSI Boot From SAN (BFS) fatal error 8 upon booting with the PowerStore appliance.
Naprakész: May 20, 2026
Azonosító: 000223454
VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Naprakész: May 20, 2026
Azonosító: 000223404
Slow insertion of a SAS or SATA drive in PowerEdge 15G or 16G Servers with a PERC or HBA controller configuration causes a "No Access" bit to be set, leading to an inability to blink and unblink drives.
Naprakész: May 20, 2026
Azonosító: 000222941
On an ESXi host, if the Flow Control setting on the BCM5720 is modified without a cable inserted, the network interface card (NIC) may fail to establish a link when a cable is later inserted. The issue does not occur if the setting is modified with a cable inserted in the NIC port.
Naprakész: May 20, 2026
Azonosító: 000222793
Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Naprakész: May 20, 2026
Azonosító: 000222201
Dell PowerEdge Server: 15G and 16G Intel-based systems may fail with bugcheck 0x139 after installing the Intel chipset drivers or Matrox video driver.
Naprakész: May 20, 2026
Azonosító: 000222177
When installing or restarting the ISM 5.1.1 on an ESXi 8.x environment, the VMK interface for BMC_Network vSwitch gets configured with a DHCP assigned address instead of static.
Naprakész: May 20, 2026
Azonosító: 000221985
Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Naprakész: May 19, 2026
Azonosító: 000221846
This article explains why the Windows Boot Drive (hosting the C:\ volume) may show as removeable media in Windows and how to override the behavior when necessary.
Naprakész: May 19, 2026
Azonosító: 000221557
The link speed of a NVIDIA ConnectX-7 Single Port NDR200 may show as Single Data Rate (SDR) in the IDRAC.
Naprakész: May 19, 2026
Azonosító: 000221452
Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Naprakész: May 19, 2026
Azonosító: 000221408
An error occurs when attempting to apply default settings to a Dell Intel E810-2C Ethernet Adapter. These adapters are configured with Permit Total Port Shutdown enabled. Both ports have Port Option set to 4x25.
Naprakész: May 19, 2026
Azonosító: 000221407
When in a SNAPI enabled configuration, the Dell Mellanox Ethernet and InfiniBand NICs may display 0000:0000:0000:0000 as the virtual node GUID for the second partition.
Naprakész: May 19, 2026
Azonosító: 000221406
Firmware upgrades to Broadcom network devices may fail with a "libpci.so: Cannot open" error when run from a Smart Bootable ISO image created with Dell Repository Manager 3.x.
Naprakész: May 19, 2026
Azonosító: 000221180
This article provides three methods to confirm the SSD Piece Part Identification (PPID)
Naprakész: May 19, 2026
Azonosító: 000466928
After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Naprakész: May 19, 2026
Azonosító: 000220891
If "Automatically restart" under System Failure is disabled inside Windows Server 2019 and 2022, a manual reboot is needed after a bug check or crash, but the system is rebooting automatically.
Naprakész: May 19, 2026
Azonosító: 000220429
The PowerEdge 15G and 16G Intel Lewisburg C62xx Chipset Dell Update package (DUP) version 10.1.19485.8386, for Windows operating system, released as part of the December 2023 release (factory and web posting) includes non-signed components from Intel for Windows Defender Application Control (WDAC).
The PowerEdge R6515/R7515 AMD Milan Chipset DUP version 2.18.30.202 (October 2023) was also found to include non-signed components from AMD for WDAC.
The PowerEdge 14G Intel platform Chipset DUP package version 10.1.18807.8279 (#K69PV) targeted for the upcoming March 2024 block has been found to have the same issue with WDAC (enforced mode) as it includes non-signed components from Intel.
Naprakész: May 19, 2026
Azonosító: 000220345
iDRAC version 6.10.00.00 and later, when 3 out of 4 partitions are enabled on a Dell Marvell QL41262 adapter, the iDRAC user interface displays the link speed as "Unknown."
Naprakész: May 19, 2026
Azonosító: 000220343