This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Naprakész: August 10, 2026
Azonosító: 000205512
This article introduces the VxRail VxVerify tool and how to successfully run VxVerify in a VxRail environment.
Naprakész: July 31, 2026
Azonosító: 000021527
Event code: VXR508TMP0118
This event code indicates "The system inlet temperature is less than the lower warning threshold."
Naprakész: August 14, 2026
Azonosító: 000011757
Event code: VXR508SWC4008
This event code indicates "A firmware or software incompatibility detected between CMC 1 and CMC 2."
Naprakész: August 14, 2026
Azonosító: 000011756
Event code: VXR508PSU0044
This event code indicates "Cannot obtain status information from power supply <number>."
Naprakész: August 14, 2026
Azonosító: 000011755
Event code: VXR508STOR13
This event code indicates "Unable to set the operation mode of the newly inserted storage sled in slot <slot number> to Split Single or Split Dual Host, because the storage sled has only one PERC controller."
Naprakész: August 14, 2026
Azonosító: 000011754
Event code: VXR508STOR18
This event code indicates "A Shared Storage device is detected in slots other than Chassis Slots 5 and 6. This configuration is not currently supported."
Naprakész: August 14, 2026
Azonosító: 000011753
Event code: VXR508RDU0017
This event code indicates "The storage power redundancy is no longer available."
Naprakész: August 14, 2026
Azonosító: 000011752
Event code: VXR508SWC4006
This event code indicates "A firmware or software incompatibility detected between system BIOS in slot <number> and CMC."
Naprakész: August 14, 2026
Azonosító: 000011751
Explore the Dell End of Service Life (EOSL) and End of Life (EOL) list for converged infrastructure, storage, and storage networking products. Access End-of-Life documents for hardware, software, and firmware release and service dates
Naprakész: August 14, 2026
Azonosító: 000185734
Event code: VXR508PWR1005
This event code indicates "The system performance degraded because of user-defined power capacity has changed."
Naprakész: August 14, 2026
Azonosító: 000011750
Event code: VXR508TMP0120
This event code indicates "The system inlet temperature is greater than the upper warning threshold."
Naprakész: August 14, 2026
Azonosító: 000011749
Event code: VXR508PDR7
This event code indicates "<physical disk> has degraded."
Naprakész: August 14, 2026
Azonosító: 000011748
Event code: VXR508PSU0005
This event code indicates "The power input for power supply <number> is outside of the allowable range, but it is attached to the system."
Naprakész: August 14, 2026
Azonosító: 000011747
Remediation is available for a vulnerability that could be exploited by malicious users to compromise the affected systems.
Naprakész: August 14, 2026
Azonosító: 000497857
Step-by-step guide using vCenter to identify failed disk, remove disk or disk group, physically replace the faulted disk, mark the new disk as local, and add a new disk or disk group.
Naprakész: August 14, 2026
Azonosító: 000019481
Event code: VXR508TMP0100
This event code indicates "The system board <name> temperature is less than the lower warning threshold."
Naprakész: August 13, 2026
Azonosító: 000011746
Software-Defined Data Center (SDDC) Manager precheck failure Multi-Site Service fails due to pantheon service in a failed state.
Service Availability: Check if the service is up and running using command "systemctl status pantheon." As root user, restart the service if required using command "systemctl restart pantheon" from SDDC Manager VM.
Naprakész: August 13, 2026
Azonosító: 000420702
Event code: VXR508STOR5
This event code indicates "Redundancy lost.<VD/Enclosure Name>"
Naprakész: August 13, 2026
Azonosító: 000011745
Event code: VXR508RDU0013
This event code indicates "Power supply redundancy is degraded."
Naprakész: August 13, 2026
Azonosító: 000011744
Event code: VXR508PSU0002
This event code indicates "A predictive failure detected on power supply <number>."
Naprakész: August 13, 2026
Azonosító: 000011743
Event code: VXR508SWC4004
This event code indicates "A firmware or software incompatibility detected between iDRAC in slot <number> and CMC."
Naprakész: August 13, 2026
Azonosító: 000011742
Event code: VXR508VLT0302
This event code indicates "CPU <number> <name> voltage is greater than the upper warning threshold."
Naprakész: August 13, 2026
Azonosító: 000011716
Event code: VXR508VLT0230
This event code indicates "The mezzanine card <number> <name> voltage is less than the lower warning threshold."
Naprakész: August 13, 2026
Azonosító: 000011715
Event code: VXR508TMPS0100
This event code indicates "Inlet temperature is above warning level for extended duration."
Naprakész: August 13, 2026
Azonosító: 000011712
Event code: VXR508VDR54
This event code indicates "<VD Name> initialization is terminated."
Naprakész: August 13, 2026
Azonosító: 000011711
Event code: VXR508PDR211
This event code indicates "<physical disk name> has encountered storage medium error."
Naprakész: August 13, 2026
Azonosító: 000011710
Event code: VXR508MEM6003
This event code indicates "Memory device status is non-critical. Memory device location: <location>, Possible memory module event cause: <cause>."
Naprakész: August 13, 2026
Azonosító: 000011709
Event code: VXR508VLT0208
This event code indicates "The memory module <number> <name> voltage is greater than the upper warning threshold."
Naprakész: August 13, 2026
Azonosító: 000011707
Event code: VXR508VLT0206
This event code indicates "The memory module <number> <name> voltage is less than the lower warning threshold."
Naprakész: August 13, 2026
Azonosító: 000011706