This document highlights minimum, recommended, and latest code versions for Dell Technologies Enterprise and Data Center Infrastructure products. Dell carefully evaluates and monitors code deployment data to ensure that product releases meet our stringent expectations to provide our customers with reliable products and solutions.
Aktualizované: July 27, 2026
Identifikátor: 000205512
Data Domain Capacity Resolution Path.
Aktualizované: July 14, 2026
Identifikátor: 000192662
Following a DD OS upgrade and reboot, certain network interfaces may not initialize successfully, resulting in missing routing rules and network connectivity issues. This behavior has been observed on systems using Intel E810 network adapters with Direct Attach (DA) cables and is resolved in DD OS 8.3.1.40 and later releases.
Aktualizované: July 28, 2026
Identifikátor: 000492292
A BoostFS mount operation may create the /tmp/Boost_D4_Event.log file due to initialization of integrated DDBoost D4 libraries. On affected releases, the file may be created with world-writable permissions; this behavior has been corrected in later BoostFS releases that apply more restrictive permissions and automatically update existing files during installation or upgrade.
Aktualizované: July 28, 2026
Identifikátor: 000492288
This article expands on Active Directory integration for Dell Data Domain systems by providing commonly used CLI commands for domain joins, OU placement, authentication configuration, domain verification, access management, CIFS share considerations, and advanced troubleshooting. It serves as a command-reference companion to the primary Active Directory guide and includes examples and best practices for validating and maintaining Active Directory connectivity.
Aktualizované: July 27, 2026
Identifikátor: 000204265
Network interfaces may go down, become intermittent, or fail to recover properly following events such as node reboots, HA failovers, link renegotiation, or other network transitions on systems equipped with Intel NICs.
This issue can occur when the Intel workaround for M14MK dual-rate transceivers remains configured after the interfaces have been migrated to W4GPP 25Gb transceivers. The resulting speed mismatch can cause interface connectivity loss and intermittent network behavior.
Aktualizované: July 27, 2026
Identifikátor: 000487314
This article provides a structured troubleshooting workflow, event-specific remediation guidance, and the most likely resolution for SDPM (NVRAM) events.
Aktualizované: July 27, 2026
Identifikátor: 000491808
This article describes how to sanitize and reconfigure Software Defined Persistent Memory (SDPM) settings in the BIOS and verify successful initialization after the system returns to DDOS.
Aktualizované: July 27, 2026
Identifikátor: 000283787
If the license is in the old format when upgrading a Data Domain controller to a new model, it fails on newer DDOS codes.
Aktualizované: July 24, 2026
Identifikátor: 000256145
MTree replication resync can fail with error "MREPL ASSOC failed: Dest MTree is WORM, source requests removal of WORM (5312)" when the source and destination MTrees have mismatched Retention Lock states. Resync operations are only supported when both MTrees have matching Data Domain Retention Lock Governance or Compliance settings.
Aktualizované: July 24, 2026
Identifikátor: 000486502
This KB article outlines comprehensive guidelines for preparing a Data Domain High Availability (DDHA) system upgrade. Adhering to these instructions guarantees a successful upgrade experience.
Aktualizované: July 24, 2026
Identifikátor: 000328991
Attempting to add a second disk pack to the active tier returns an error stating a partial shelf must be fully used first. The failure is caused by an insufficient capacity license that leaves the initial shelf only partially consumed.
Aktualizované: July 24, 2026
Identifikátor: 000489909
A VLAN interface became inaccessible after a reboot because an invalid MTU configuration was rejected during initial configuration but still persisted in the registry, causing the interface to fail when the system later attempted to apply the invalid MTU during interface initialization.
Aktualizované: July 24, 2026
Identifikátor: 000486074
KB explains a possible reason why an on-premise DDVE running off VMware may be seen to reboot every few minutes with leaving no traces or logs in the DDOS
Aktualizované: July 23, 2026
Identifikátor: 000078099
Migration send may fail with active critical alerts when the destination hostname specified in the migration command does not match the destination hostname defined in the replication context. Ensure the hostname used in the migration send command matches the destination system hostname configured in the replication context.
Aktualizované: July 20, 2026
Identifikátor: 000486123
A Dell Data Domain DD6400/6410 system may intermittently generate false "EVT-STORAGE-00039: RAID reconstruction is in progress" alerts even though no disk failures, disk errors, or active RAID rebuilds exist.
Aktualizované: July 20, 2026
Identifikátor: 000438471
A Data Domain (DD) system generates alert EVT-ENVIRONMENT-00029 with the message "I/O module has failed" when a PCIe I/O module (also known as a SLIC or PCI card) fails or is removed. Affected card types include SAS, NIC, NVRAM, and Fibre Channel (FC).
Aktualizované: July 20, 2026
Identifikátor: 000203868
This article provides download links and status information for current PowerProtect Data Domain Operating System (DDOS) releases, including feature and Long‑Term Support (LTS) versions. It also outlines upgrade considerations, documentation references, and supported platforms.
Aktualizované: July 16, 2026
Identifikátor: 000081247
Summary: DDOS precheck fails because of an old certificate in the trust chain.
Aktualizované: July 15, 2026
Identifikátor: 000215203
When applying a .lic license file to a Data Domain system, the operation fails because the system requires an XML-formatted license file.
Aktualizované: July 14, 2026
Identifikátor: 000223025
Summary: This document details the steps to register/add a Data Domain System to Secure Connect Gateway while using connectemc.
Aktualizované: July 14, 2026
Identifikátor: 000197719
Clear entries by removing PostgreSQL DB and reinstalling Avamar REST API rpm package.Troubleshoot backup failure by checking software version and client properties on NMC1.
Aktualizované: July 14, 2026
Identifikátor: 000364008
How to reset or regenerate certificates due to expiration (or misconfiguration).
Aktualizované: July 14, 2026
Identifikátor: 000188770
Starting with DD OS 8.4, firmware-based LLDP is disabled by default on supported Intel NICs to prevent network stability issues affecting LACP, bonded interfaces, and HA communication. This change addresses multiple field-observed issues including transmit timeouts, intermittent connectivity, and heartbeat failures.
Aktualizované: July 14, 2026
Identifikátor: 000487613
The primary focus for this article is to troubleshoot an interface down, multiple interfaces down, an intermittent interface, and a bad network card. Replacing parts should be the last step in resolving interface down issues. Troubleshooting these issues first such as reviewing the switch side, may lead to the quickest resolution.
Aktualizované: July 13, 2026
Identifikátor: 000219757
This article provides a clear, model‑by‑model breakdown of the recommended BIOS and iDRAC firmware versions for each supported DDOS release across the DD series platforms. It is designed to help you quickly confirm which firmware levels align with your system’s DDOS version, reduce compatibility issues, and ensure that your environment stays stable, secure, and fully supported. Use the tables below to find the right BIOS and iDRAC versions for your specific DD model in seconds.
Aktualizované: July 13, 2026
Identifikátor: 000434577
This article describes how to identify and resolve memory-related errors on Dell Data Domain systems.
Aktualizované: July 13, 2026
Identifikátor: 000204330
When using failover bonding, the standby interface has many dropped packets. This is expected since the standby interface is not active.
Aktualizované: July 13, 2026
Identifikátor: 000200178
This article describes a specific circumstance where space reclamation may not proceed despite a lack of media database records for the files in question.
Aktualizované: July 10, 2026
Identifikátor: 000479324
Data Domain systems initiate a graceful shutdown if multiple disk failures occur and RAID reconstruction cannot proceed. This protective measure prevents potential data loss when RAID protection reaches a critical state.
Aktualizované: July 10, 2026
Identifikátor: 000203752