跳转至主要内容
获得完全访问权限。
登录
创建账户
获得完全访问权限。
登录
创建账户
OEMR 1850 image

OEMR 1850

OEMR 1850

文章

输入无效。请仅使用字母、数字和除 <>)(%/;,=#-/* 之外的任何特殊字符

已显示 30 个,共 80 个
已显示 80 个,共 80 个

PowerEdge 嵌入式 LifeCycle Controller 提供了使用操作系统部署功能安装受支持的 Windows Server 和 Linux 服务器操作系统的简化方法。 本文介绍如何使用 iDARC LifeCycle Controller 在大多数 Dell PowerEdge 服务器上安装受支持的操作系统。使用 LifeCycle Controller 安装 Windows Server、Ubuntu Server LTS、SUSE Linux Enterprise Server 或 Red Hat Enterprise Linux 的分步说明和操作系统安装视频
更新:  六月 25, 2026 ID: 000130160

本文提供有关如何验证网络接口卡 (NIC) 是否与 PowerEdge 服务器兼容的信息。
更新:  五月 23, 2026 ID: 000349619

To replace a CMOS battery, remove the air shroud, disconnect and remove any expansion cards, locate the battery socket, and carefully pry out the CMOS battery. After installing a new CMOS battery, you must reinstall the expansion cards, install the air shroud, and restore the BIOS settings, ensuring the battery is operating properly and the correct data and time are set in the System Setup.
更新:  六月 25, 2026 ID: 000234357

本文介绍在本地和远程重置 Integrated Dell Remote Access Controller (iDRAC) 的多种方法,包括重置、重置为默认值和重置为客户配置。
更新:  六月 25, 2026 ID: 000126703

When running the nvidia-smi command, you may encounter a driver error stating that "nvidia-smi has failed because it could not communicate with the NVIDIA driver.
更新:  六月 24, 2026 ID: 000252982

This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
更新:  六月 24, 2026 ID: 000143247

这是一个固件目录,其中包含适用于选定 Dell VMware vSAN 就绪节点的经过验证和认证的固件堆栈。
更新:  六月 24, 2026 ID: 000183111

本文讨论如何使用 PowerShell 管理 Windows Server Update Services (WSUS) 角色。详细介绍了用于添加 WSUS 角色和执行各种管理任务的 PowerShell 命令。
更新:  六月 20, 2026 ID: 000121387

本文介绍如何使用和设置 Integrated Dell Remote Access Controller (iDRAC) 6、7、8 或 9 的虚拟介质功能。
更新:  六月 20, 2026 ID: 000124001

本文提供有关如何使用 LCC 部署受支持的操作系统的信息。
更新:  六月 19, 2026 ID: 000334676

通过企业服务数据分析和可视化,在 MyService360 控制面板中查找答案和资源以快速入门或执行更多操作。
更新:  六月 15, 2026 ID: 000124666

How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
更新:  六月 01, 2026 ID: 000179543

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
更新:  五月 23, 2026 ID: 000349127

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
更新:  五月 23, 2026 ID: 000321587

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
更新:  五月 22, 2026 ID: 000256907

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
更新:  五月 21, 2026 ID: 000237298

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
更新:  五月 21, 2026 ID: 000227912

Dell solid state drive (SSD) fails after system reports low environment operating temperature.
更新:  五月 20, 2026 ID: 000224458

Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
更新:  五月 20, 2026 ID: 000222201

Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
更新:  五月 19, 2026 ID: 000221846

In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
更新:  五月 19, 2026 ID: 000221490

This article addresses an issue in which conversion of Windows Server from an evaluation to a fully licensed edition fails. The error that is returned appears to indicate a problem with the supplied product key, but the key is known to be valid.
更新:  五月 15, 2026 ID: 000204465

PowerEdge 服务器硬盘的固件是服务器系统中的关键组件。定期更新和维护此固件对于服务器性能、安全性和兼容性至关重要。 硬盘固件更新通常可以修复已知的硬件故障和问题,解决已识别的漏洞和安全问题,并可能引入新功能、改进和增强功能。
更新:  五月 15, 2026 ID: 000455478

The VM does not turn on after configuring PCI Device passthrough on the ESXi host and adding the device to the VM. It gets stuck at 80% and then results in an error "total number of pages needed (4206594) exceeds the limit (917504)."
更新:  五月 14, 2026 ID: 000199172

This article provides information about an EasyRestore Identity Module (IDM) failure and being unable to install the IDM manually.
更新:  五月 13, 2026 ID: 000197290

The article is a solution to fixing the issue of the system asking for eh product key after making a hardware change.
更新:  五月 13, 2026 ID: 000201865

This article explains how to generate a troubleshooting log for PowerVault TL2000/TL4000 using the graphical interface for recent firmware or Telnet for older versions.
更新:  五月 13, 2026 ID: 000139718

This article provides information about how to set up your network so the CMC and the iDRAC can dynamically update the DNS.
更新:  五月 13, 2026 ID: 000138281

Dell Enterprise solid state drives are developed to precisely match the Dell Enterprise systems and to provide an optimal production environment.
更新:  五月 13, 2026 ID: 000137759

Steps on how to clear NVRAM using Lifecycle Controller remotely using the retire and repurpose process.
更新:  五月 13, 2026 ID: 000198446