文章
Tooltip title
選取類別,然後選取相關元件,以尋找有關特定硬體和軟體的文章。
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 668 個
顯示 668 個,共 668 個
本文提供了对 PowerEdge 服务器的机箱防盗和机箱打开消息进行故障处理的步骤。
已更新: 五月 25, 2026
ID: 000136481
本文提供有关导入 iDRAC 许可证时出现的 LIC008 错误的信息。
已更新: 五月 23, 2026
ID: 000353269
背板固件更新作业失败并显示SUP0517错误。
已更新: 五月 25, 2026
ID: 000200703
本文档重点介绍 Dell Technologies PowerEdge 产品的最低代码版本、建议代码版本和最新版本。我们会仔细评估和监控代码部署数据,以确保产品版本符合我们严格的期望,为客户提供可靠的产品和解决方案。
已更新: 五月 25, 2026
ID: 000227230
以下文章是从少数版本的 iDRAC 的关键日志条目“SWC5008无法访问前 LED 面板”恢复 PowerEdge 系统的解决机制。
已更新: 五月 25, 2026
ID: 000205597
NVIDIA has updated the signing certificate for its UEFI network driver from Microsoft UEFI CA 2011 to Microsoft UEFI CA 2023. PowerEdge 17G platforms already trust the CA 2023 certificate, but 15G/16G and earlier servers require a BIOS update released in December 2025. Systems without this updated certificate support may fail to initialize the NIC UEFI driver when Secure Boot is enabled.
已更新: 五月 24, 2026
ID: 000420051
PowerEdge T150/R250/R350/T350 BIOS version 1.13.0 shows an incorrect release date in the operating system (OS) due to a System Management BIOS (SMBIOS) cosmetic issue.
已更新: 五月 24, 2026
ID: 000414845
Server BIOS Update Guidelines for Microsoft Secure Boot Certificates are provided in this article.
已更新: 五月 24, 2026
ID: 000402373
PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
已更新: 五月 24, 2026
ID: 000396285
Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
已更新: 五月 24, 2026
ID: 000391086
Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
已更新: 五月 24, 2026
ID: 000379421
Dell Chicony power supply (X1HXF) reports an Under Voltage Fault event PSU0034.
已更新: 五月 23, 2026
ID: 000353410
This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
已更新: 五月 23, 2026
ID: 000349619
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
已更新: 五月 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
已更新: 五月 23, 2026
ID: 000333712
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
已更新: 五月 23, 2026
ID: 000333265
New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
已更新: 五月 23, 2026
ID: 000326459
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
已更新: 五月 23, 2026
ID: 000321587
PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
已更新: 五月 23, 2026
ID: 000314166
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
已更新: 五月 23, 2026
ID: 000311902
The "Predictive failure reported for disk x" error continues to be logged every 24 hours, even after the identified drive has been replaced. The issue only affects drives connected to PERC Controllers in RAID configuration.
已更新: 五月 23, 2026
ID: 000308774
第 15 代 PowerEdge 服务器在发生事件后无响应或停止PST0210响应。
已更新: 五月 22, 2026
ID: 000297851
During Windows Server 2025 installation by iDRAC virtual media, a disk with size 0 B is displayed on the drive selection page.
已更新: 五月 22, 2026
ID: 000278171
Leveraging the 'Reboot Required' filter and selecting all items in this filtered view results in the 'make compliant' job applying all non-compliant firmware components. An unexpected reboot of the target is seen as components that do require a restart are deployed to the target. The issue is only seen if selecting all objects and using the 'Reboot Required' filter. All other filters work as designed.
已更新: 五月 22, 2026
ID: 000270340
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
已更新: 五月 22, 2026
ID: 000256907
CPUs can be perceived to be hot while server is idle.
已更新: 五月 22, 2026
ID: 000250878
Beginning with 15G PowerEdge, servers are offered in configurations that report more drive connections than are physically available.
已更新: 五月 22, 2026
ID: 000250643
All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
已更新: 五月 22, 2026
ID: 000246018
在连续重新启动测试期间,由于 PowerEdge T150、R250、R350、T350 系统上的内部错误 (CPU0000),系统可能会在关机阶段停止响应。
已更新: 五月 22, 2026
ID: 000245052
在 ESXi 8.0 U3 安装期间观察到系统停止响应或紫屏死机 (PSOD),
已更新: 五月 21, 2026
ID: 000241608