文章
Tooltip title
選取類別,然後選取相關元件,以尋找有關特定硬體和軟體的文章。
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 813 個
顯示 813 個,共 813 個
本文提供有关导入 iDRAC 许可证时出现的 LIC008 错误的信息。
已更新: 五月 23, 2026
ID: 000353269
本文提供有关如何验证网络接口卡 (NIC) 是否与 PowerEdge 服务器兼容的信息。
已更新: 五月 23, 2026
ID: 000349619
This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
已更新: 五月 23, 2026
ID: 000349127
Unsure about the procedure to update a specific component's firmware in a PowerEdge system? Learn how to in this specific article.
已更新: 五月 23, 2026
ID: 000333712
Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
已更新: 五月 23, 2026
ID: 000333265
New deployments of OpenManage Enterprise 4.4.0 are experiencing service failures after configuring the time zone for GMT +02:00 Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. The issue is only seen on fresh deployment of OpenManage Enterprise (OME) 4.4.0 on Hyper-V. Deploying OpenManage Enterprise (OME) on other hypervisors is not impacted.
已更新: 五月 23, 2026
ID: 000326459
R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
已更新: 五月 23, 2026
ID: 000321587
Dell Enterprise NVMe solid state drives may be leveraged as a substitute for Dell Data Center NVMe solid state drives.
已更新: 五月 23, 2026
ID: 000315161
PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
已更新: 五月 23, 2026
ID: 000314166
Dell Technologies advises against downgrading Hard Drive or SSD firmware, except in validated scenarios, due to unpredictable results and version reporting issues.
已更新: 五月 23, 2026
ID: 000311902
After a system restart, the Integrated Dell Remote Access Controller (iDRAC) may not display the Virtual Disk information intermittently.
已更新: 五月 22, 2026
ID: 000303213
第 15 代 PowerEdge 服务器在发生事件后无响应或停止PST0210响应。
已更新: 五月 22, 2026
ID: 000297851
Leveraging the 'Reboot Required' filter and selecting all items in this filtered view results in the 'make compliant' job applying all non-compliant firmware components. An unexpected reboot of the target is seen as components that do require a restart are deployed to the target. The issue is only seen if selecting all objects and using the 'Reboot Required' filter. All other filters work as designed.
已更新: 五月 22, 2026
ID: 000270340
Performing a "yum update" check for Red Hat Enterprise Linux or SuSE Linux for Enterprise Servers updates may fail due to improper iDRAC RPM in the Dell YUM repository on linux.dell.com.
已更新: 五月 22, 2026
ID: 000262378
PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
已更新: 五月 22, 2026
ID: 000256907
DSU and SUU may not inventory any server components due to a crash caused in the invcol.exe module. Inventory Collector 24.09 and newer is no longer fully compatible with Windows Server 2016.
已更新: 五月 22, 2026
ID: 000251806
CPUs can be perceived to be hot while server is idle.
已更新: 五月 22, 2026
ID: 000250878
Various Dell enterprise products behave unexpectedly if IPMI is intentionally disabled from communicating between the operating system and iDRAC. This can be done by disabling the "In-band Management Interface" setting in BIOS System Security settings.
已更新: 五月 22, 2026
ID: 000247770
All products: Contaminants such as dust on fiber optic connector end face causes poor IO performance
Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
已更新: 五月 22, 2026
ID: 000246018
在 ESXi 8.0 U3 安装期间观察到系统停止响应或紫屏死机 (PSOD),
已更新: 五月 21, 2026
ID: 000241608
iDRAC Service Module (iSM) 5.4 and older versions fail to upload SupportAssist collections back to Dell. A "handshake API" error occurs. This upload feature has been deprecated due to the receiving servers at Dell had been decommissioned.
已更新: 五月 21, 2026
ID: 000240336
本文可帮助您在戴尔支持站点上找到并下载较旧版本的适用于 ESXI 的戴尔自定义 ISO。
已更新: 五月 21, 2026
ID: 000238184
这是 Dell OpenManage Enterprise 4.3.x 支持矩阵的最新版本。
已更新: 五月 21, 2026
ID: 000237971
The Dell SS540 SAS solid state drive is reported as not correctly functioning.
已更新: 五月 21, 2026
ID: 000237298
PowerEdge servers with Emulex Fiber Channel (FC) driver version 12.01.12 may fail driver installation under Windows Defender Application Control (WDAC) Enforced Mode on Windows Server.
已更新: 五月 21, 2026
ID: 000236792
PowerEdge: Broadcom NXE devices with Driver 229.2.73 (SWB: Y7T4X) may report that the interfaces are missing in the operating system when secure boot is enabled.
已更新: 五月 21, 2026
ID: 000236776
In some instances, the firmware update job may fail to initiate when performing a firmware update through available iDRAC interfaces.
已更新: 五月 21, 2026
ID: 000234480
This article provides a step-by-step guide on how to remove and install a cooling fan on a Dell system. These instructions are applicable to both standard and high-performance fans. The guide covers the removal and installation of the cooling fan assembly.
已更新: 五月 21, 2026
ID: 000234366
In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
已更新: 五月 21, 2026
ID: 000233949
OpenManage Enterprise integration for VMware vCenter may fail to Unmanage hosts with error "UNMANAGE_REMOVE_MEL_FAILURE"
已更新: 五月 21, 2026
ID: 000233873