文章
Tooltip title
選取類別,然後選取相關元件,以尋找有關特定硬體和軟體的文章。
輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元
顯示 30 個,共 818 個
顯示 818 個,共 818 個
以下文章提供有关 Dell PowerEdge 系统上的 BIOS、Lifecycle Controller 和 Integrated Dell Access Controller (iDRAC) 中可用的“语言”选项以及如何对其进行更改的信息。
已更新: 五月 12, 2026
ID: 000135184
不确定更新 PowerEdge 系统中特定组件固件的过程?在此特定文章中了解应该怎么做。
已更新: 五月 12, 2026
ID: 000333712
Does running a CPU at high temperatures for extended periods of time impact its quality and lifespan?
已更新: 五月 12, 2026
ID: 000212668
This article provides information about how to boot past the Driver Health Manager Screen.
已更新: 五月 12, 2026
ID: 000148089
This article provides information about Dell Boot Optimized Storage Solution (BOSS) PCIe cards. It also provides instructions for installing Windows, Red Hat, SuSE, Ubuntu, and related Linux distributions onto these cards.
已更新: 五月 12, 2026
ID: 000177584
This article provides information about how to troubleshoot PCIe devices that are not being detected correctly.
已更新: 五月 12, 2026
ID: 000300035
OpenManage Enterprise: Error in Devices/Groups tab while creating repository in Update Manager Plugin 1.2
已更新: 五月 12, 2026
ID: 000195162
本文提供了有关管理安装在基于英特尔的第 14 代和第 15 代 PowerEdge 服务器以及基于 AMD 的第 15 代 PowerEdge 服务器中的 DDR4 RDIMM 或 LRDIMM 上的可纠正错误阈值事件(MEM0802 或 MEM5104)的更新建议。
已更新: 五月 12, 2026
ID: 000194574
[OpenManage Enterprise (OME) Power-Manager 插件]无法检索电源信息。
已更新: 五月 12, 2026
ID: 000210330
Dell PowerEdge Server remediation is available for Dell AMD-based Graphics Driver Vulnerabilities that could be exploited by malicious users to compromise the affected systems.
已更新: 五月 12, 2026
ID: 000464072
Dell PowerEdge Server remediation is available for Dell AMD-based Graphics Driver Vulnerability that could be exploited by malicious users to compromise the affected systems.
已更新: 五月 12, 2026
ID: 000464075
Dell PowerEdge Server remediation is available for Dell AMD-based PowerEdge Server Vulnerability that could be exploited by malicious users to compromise the affected systems.
已更新: 五月 12, 2026
ID: 000464069
Windows 2022 has not removed any features from Hyper-V or networking. However, they have forced LBFO Virtual switches to the Command line for creation.
While nothing has changed, the Vmswitch fails to create, as normal. The Error is Failed while adding Virtual Ethernet Switch Connections. Attaching a virtual switch to an LBFO team is Deprecated.
The only way around this error is to add "-AllowNetLbfoTeams $true"
this will require PowerShell and may be a call generator.
已更新: 五月 12, 2026
ID: 000193974
This article gives the steps for resetting the 120-day Remote Desktop Services licensing grace period in Windows Server.
已更新: 五月 12, 2026
ID: 000193714
How to repair No Boot Missing or Corrupt BCD on Windows OS.
已更新: 五月 12, 2026
ID: 000193581
The FLtmc Checker tool looks up filter drivers.
已更新: 五月 12, 2026
ID: 000193575
Use the BOILER Tool to Analyze CBS/DISM logs to provide suggestions on a resolution.
已更新: 五月 12, 2026
ID: 000193563
Dell OpenManage Server Administrator 10.1.0 and later no longer responds to direct WMI or SNMP queries from six DELL_CMxxxx classes of various system inventory items. This is due to a Dell engineering's decision to remove the underlying Inventory Collector (IC) module for both security and installation package size constraints.
已更新: 五月 12, 2026
ID: 000193542
Dell Repository Manager 3.3.2 job exporting a repository to a Software update Utility (SUU) image may end with a "Partial Success" status. Further job details contain the message "Falling back to default inventory collector carried." However, the SUU image should perform applying all applicable DUP packages.
已更新: 五月 12, 2026
ID: 000193509
Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
已更新: 五月 12, 2026
ID: 000227413
This KB talks about Dell's VMware ESXi 8.0 release in general in terms of certified components.
已更新: 五月 12, 2026
ID: 000217592
This article provides a video and troubleshooting options for iDRAC connectivity issues.
已更新: 五月 12, 2026
ID: 000185547
This article describes an issue affecting PowerEdge servers running iDRAC9 in which the error SWC5008 asserts in the SEL multiple times.
已更新: 五月 12, 2026
ID: 000181333
This article provides different methods to get the iDRAC IP address of your PowerEdge servers directly from the VMware ESXi host. It is useful when you do not have physical access to the server.
已更新: 五月 12, 2026
ID: 000143172
This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 8.X branch Images.
已更新: 五月 12, 2026
ID: 000225254
This article contains instructions for testing LDAPS connectivity on a Windows domain controller and how to enable LDAPS for use with Dell products.
已更新: 五月 11, 2026
ID: 000213104
This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
已更新: 五月 11, 2026
ID: 000127944
This article is a step-by-step guide on how to replace a hard drive.
已更新: 五月 11, 2026
ID: 000143539
The Integrated Dell Remote Access Controller 9 (iDRAC9) provides comprehensive, embedded management across the PowerEdge family of servers. IDRAC9 automation that lets your organization grow, and security that ensures peace of mind. It is a key technology in the OpenManage portfolio. Users can build a management solution that matches your needs, and by leveraging iDRAC, ensures optimal server management.
已更新: 五月 11, 2026
ID: 000178016
我们收到了有关 ESXi 7.0 和 ESXi 8.0 的最新 VMware 修补程序版本自定义 ISO 的若干请求。新的 VMware 修补程序包括针对漏洞 CVE-2025-22224、CVE-2025-22225 和 CVE-2025-22226 的关键安全更新。VMSA-2025-0004 是 Broadcom 官方文章编号,通常用于向技术支持解释问题。
已更新: 五月 11, 2026
ID: 000291363