跳至主要內容
取得完整存取權。
登入
建立帳戶
取得完整存取權。
登入
建立帳戶
PowerEdge R940xa image

PowerEdge R940xa

PowerEdge R940xa

文章

選取類別,然後選取相關元件,以尋找有關特定硬體和軟體的文章。

輸入的內容無效。請僅使用字母、數字和 <>)(%/;,=#-/* 以外的任何特殊字元

顯示 30 個,共 782 個
顯示 782 個,共 782 個

以下文章提供有关 Dell PowerEdge 系统上的 BIOS、Lifecycle Controller 和 Integrated Dell Access Controller (iDRAC) 中可用的“语言”选项以及如何对其进行更改的信息。
已更新:  五月 12, 2026 ID: 000135184

不确定更新 PowerEdge 系统中特定组件固件的过程?在此特定文章中了解应该怎么做。
已更新:  五月 12, 2026 ID: 000333712

如何捕获 Storport 跟踪以帮助对存储延迟问题进行故障处理。
已更新:  五月 13, 2026 ID: 000195728

This is a brief demonstration of how to use logman, relog, and typerf to collect performance logs useful in troubleshooting slow performance conditions.
已更新:  五月 13, 2026 ID: 000195727

Dell customers may report an unrecoverable hardware error on POST with configurations including a certain mix of Mellanox firmware, BIOS, and iDRAC versions. While the issue was reported on VMware with CX-5 cards, other Dell/Mellanox hardware may be affected.
已更新:  五月 13, 2026 ID: 000195461

Steps on how to clear NVRAM using Lifecycle Controller remotely using the retire and repurpose process.
已更新:  五月 13, 2026 ID: 000198446

Does running a CPU at high temperatures for extended periods of time impact its quality and lifespan?
已更新:  五月 12, 2026 ID: 000212668

This article provides information about how to boot past the Driver Health Manager Screen.
已更新:  五月 12, 2026 ID: 000148089

This article provides information about Dell Boot Optimized Storage Solution (BOSS) PCIe cards. It also provides instructions for installing Windows, Red Hat, SuSE, Ubuntu, and related Linux distributions onto these cards.
已更新:  五月 12, 2026 ID: 000177584

This article provides information about how to troubleshoot PCIe devices that are not being detected correctly.
已更新:  五月 12, 2026 ID: 000300035

OpenManage Enterprise: Error in Devices/Groups tab while creating repository in Update Manager Plugin 1.2
已更新:  五月 12, 2026 ID: 000195162

本文提供了有关管理安装在基于英特尔的第 14 代和第 15 代 PowerEdge 服务器以及基于 AMD 的第 15 代 PowerEdge 服务器中的 DDR4 RDIMM 或 LRDIMM 上的可纠正错误阈值事件(MEM0802 或 MEM5104)的更新建议。
已更新:  五月 12, 2026 ID: 000194574

Windows 2022 has not removed any features from Hyper-V or networking. However, they have forced LBFO Virtual switches to the Command line for creation. While nothing has changed, the Vmswitch fails to create, as normal. The Error is Failed while adding Virtual Ethernet Switch Connections. Attaching a virtual switch to an LBFO team is Deprecated. The only way around this error is to add "-AllowNetLbfoTeams $true" this will require PowerShell and may be a call generator.
已更新:  五月 12, 2026 ID: 000193974

This article gives the steps for resetting the 120-day Remote Desktop Services licensing grace period in Windows Server.
已更新:  五月 12, 2026 ID: 000193714

How to repair No Boot Missing or Corrupt BCD on Windows OS.
已更新:  五月 12, 2026 ID: 000193581

The FLtmc Checker tool looks up filter drivers.
已更新:  五月 12, 2026 ID: 000193575

Use the BOILER Tool to Analyze CBS/DISM logs to provide suggestions on a resolution.
已更新:  五月 12, 2026 ID: 000193563

Dell OpenManage Server Administrator 10.1.0 and later no longer responds to direct WMI or SNMP queries from six DELL_CMxxxx classes of various system inventory items. This is due to a Dell engineering's decision to remove the underlying Inventory Collector (IC) module for both security and installation package size constraints.
已更新:  五月 12, 2026 ID: 000193542

Dell Repository Manager 3.3.2 job exporting a repository to a Software update Utility (SUU) image may end with a "Partial Success" status. Further job details contain the message "Falling back to default inventory collector carried." However, the SUU image should perform applying all applicable DUP packages.
已更新:  五月 12, 2026 ID: 000193509

Dell has introduced significant updates to how PowerEdge servers manage coin-cell (CMOS) battery functionality and related event logging. Beginning with 14th Generation (14G) servers in August 2024 — through iDRAC and BIOS firmware updates — and extending to 15G and 16G platforms from February 2025 onward, several key changes have been implemented
已更新:  五月 12, 2026 ID: 000227413

This KB talks about Dell's VMware ESXi 8.0 release in general in terms of certified components.
已更新:  五月 12, 2026 ID: 000217592

This article provides a high-level explanation for updating the BIOS and iDRAC9 firmware versions for 14th generation PowerEdge servers.
已更新:  五月 12, 2026 ID: 000215873

This article provides a video and troubleshooting options for iDRAC connectivity issues.
已更新:  五月 12, 2026 ID: 000185547

Dell TPM 1.2 and 2.0 solutions are one of the few TPM solutions that are enhanced by full certification.
已更新:  五月 12, 2026 ID: 000137276

This article describes an issue affecting PowerEdge servers running iDRAC9 in which the error SWC5008 asserts in the SEL multiple times.
已更新:  五月 12, 2026 ID: 000181333

This article provides different methods to get the iDRAC IP address of your PowerEdge servers directly from the VMware ESXi host. It is useful when you do not have physical access to the server.
已更新:  五月 12, 2026 ID: 000143172

This article contains instructions for testing LDAPS connectivity on a Windows domain controller and how to enable LDAPS for use with Dell products.
已更新:  五月 11, 2026 ID: 000213104

This article details the procedure to troubleshoot power supply unit (PSU) issues that may arise on a PowerEdge Server.
已更新:  五月 11, 2026 ID: 000127944

This article is a step-by-step guide on how to replace a hard drive.
已更新:  五月 11, 2026 ID: 000143539

The Integrated Dell Remote Access Controller 9 (iDRAC9) provides comprehensive, embedded management across the PowerEdge family of servers. IDRAC9 automation that lets your organization grow, and security that ensures peace of mind. It is a key technology in the OpenManage portfolio. Users can build a management solution that matches your needs, and by leveraging iDRAC, ensures optimal server management.
已更新:  五月 11, 2026 ID: 000178016