Event ID — 2076

Description
Virtual disk Check Consistency failed.
Severity
Critical / Failure / Error
Cause and Action
Cause: AA physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk can cause errors in parity information.

Action: Replace the failed physical disk. You can identify which disk has failed by locating the disk that has a red “ X” for its status. Rebuild the physical disk. When finished, restart the check consistency operation.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2081