Server Administrator Version 7.4 Messages Reference Guide

PDF

Event ID — 2204

Description
A dedicated hot spare has been removed.
Severity
OK / Normal / Informational
Cause and Action
Cause: The controller is unable to communicate with a disk that is assigned as a dedicated hot spare. The disk may have been removed. There may also be a bad or loose cable.

Action: Check if the disk is healthy and that it has not been removed. Check the cables. If necessary, replace the disk and reassign the hot spare.

Related Alert Information
Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: None

SNMP Trap Numbers
901