Event ID — 2305

Description
The physical disk is too small to be used for a rebuild.
Severity
Warning / Non-critical
Cause and Action
Cause: The physical disk is too small to rebuild the data.

Action: Remove the physical disk and insert a new physical disk that is the same size or larger than the disk that is being rebuilt. The new physical disk must also use the same technology (for example, SAS or SATA) as the disk being rebuilt. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task. See the Server Administrator Storage Management User’s Guide for more information.

Related Alert Information
Clear Alert Number: None

Related Alert Number: 2326

Local Response Agent (LRA) Number: 2070

SNMP Trap Numbers
903