Virtual machines report guest data consistency errors after disk extend operation

Description:
Virtual machines running on VMware vSAN 6.6 and later report guest data consistency errors following a disk extend operation. This is a rare occurrence, requiring specific conditions to be met.
Applies to:
ESXi 6.5.x
Workaround:
VMware recommends the following workaround:
  1. Log in to the ESXi host through SSH with username as root.
  2. To set the Inplace Expansion value to 0, run the following command:
    # esxcfg-advcfg -s 0 /VSAN/ClomEnableInplaceExpansion
  3. To confirm that the value is set to 0, run the following command:
    # esxcfg-advcfg -g /VSAN/ClomEnableInplaceExpansion
  4. Repeat this process on all ESXi hosts in the vSAN cluster.
For more information, see the VMware KB article 58715.
Systems affected:
All Dell EMC PowerEdge servers
Tracking number:
NA