Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.
Some article numbers may have changed. If this isn't what you're looking for, try searching all articles. Search articles

Dell PERC controller Auto Replace Member on Predictive Failure

Summary: How to configure Auto Replace Member on Predictive Failure

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

SLN292302_en_US__1HDDJP-error green Replace Member on predictive failure can help ensure your virtual drive health stays optimal.

Cause

-

Resolution

A Replace Member operation can occur when there is a SMART predictive failure reporting on a drive in a virtual disk.

How the option works

The automatic Replace Member is initiated when the first SMART error occurs on a physical disk that is part of a virtual disk. The target drive needs to be a hot spare that qualifies as a rebuild drive. The physical disk with the SMART error is marked as failed only after the successful completion of the Replace Member. This avoids putting the array in degraded status.

If an automatic Replace Member occurs using a source drive that was originally a hot spare (that was used in a rebuild), and a new drive added for the Replace Member operation as the target drive, the hot spare reverts to the hot spare state after a successful Replace Member operation.
 

How to configure Auto Replace Member on Predictive Failure

To enable the Auto replace member on predictive failure feature you will need to:

  1. Login to OMSA with admin rights.
  2. On the left Expand Storage, you will find the PERC controller listed beneath. Select this controller.
  3. Now in the main window on the upper properties bar, select information/Configuration.
    • The right hand window will refresh with the controller properties windows.
  4. You will then need to scroll about a quarter of the way down to the Controller Tasks Drop down menu.
  5. From this select Change Properties.
  6. Choose to enable the option that says "Auto replace member on predictive failure" and execute the command.

Article Properties


Affected Product
PowerEdge, PowerEdge RAID Controller CERC 6i, PowerEdge RAID Controller 6i, PowerEdge RAID Controller H310, PowerEdge RAID Controller H700, PowerEdge RAID Controller H710, PowerEdge RAID Controller H710P, PowerEdge RAID Controller H800 , PowerEdge RAID Controller H810 ...
Last Published Date

23 Sept 2021

Version

3

Article Type

Solution