DSA-2020-128: iDRAC Local File Inclusion Vulnerability

Résumé: DSA-2020-128: iDRAC Local File Inclusion Vulnerability - CVE-2020-5366

Contenu de l’article


Impact

High

Détails

  • Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal")

CVE-2020-5366

Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.

7.1 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L

  • Improper Limitation of a Pathname to a Restricted Directory ("Path Traversal")

CVE-2020-5366

Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.

7.1 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L

Dell Technologies recommande à tous les clients de prendre en compte à la fois le score de base CVSS et les scores temporels et environnementaux pertinents qui peuvent avoir un impact sur la gravité potentielle associée à une faille de sécurité donnée.

Produits concernés et mesure corrective

Affected products:

  • Dell EMC iDRAC9 versions prior to 4.20.20.20

Resolution:   
The following Dell EMC iDRAC firmware releases contain resolutions to these vulnerabilities:

iDRAC iDRAC firmware version
iDRAC9 4.20.20.20

Note: Available as of the publication date.

Dell EMC recommends all customers upgrade at the earliest opportunity. 


Dell EMC Best Practices regarding iDRAC:

  • The iDRAC is intended to be on a separate management network. The iDRAC is not designed nor intended to be placed on, nor connected directly to the Internet. Doing so could expose the connected system to security and other risks for which Dell EMC is not responsible.
  • Dell EMC recommends using the Dedicated Gigabit Ethernet port available on rack and tower servers to connect the iDRAC to a separate management network.
  • Along with locating iDRAC on a separate management network, users should isolate the management subnet/vLAN with technologies such as firewalls, and limit access to the subnet/vLAN to authorized server administrators.
  • Dell EMC recommends using 256-bit encryption strength as well as TLS 1.2 or higher. For tighter control, additional ciphers may be removed via "Cipher Select" – see the iDRAC User Guide for more details. 
  • Dell EMC recommends additional settings such as IP range filtering and System Lockdown Mode. 
  • Dell EMC recommends using additional security authentication options such as Microsoft Active Directory or LDAP.
  • Dell EMC recommends keeping iDRAC firmware up to date.

Customers can download software, including the latest release of iDRAC firmware, from the Dell Support site.
https://www.dell.com/support/home/
Customers can find the iDRAC documentation from the Dell EMC Support site.
www.dell.com/idracmanuals

Affected products:

  • Dell EMC iDRAC9 versions prior to 4.20.20.20

Resolution:   
The following Dell EMC iDRAC firmware releases contain resolutions to these vulnerabilities:

iDRAC iDRAC firmware version
iDRAC9 4.20.20.20

Note: Available as of the publication date.

Dell EMC recommends all customers upgrade at the earliest opportunity. 


Dell EMC Best Practices regarding iDRAC:

  • The iDRAC is intended to be on a separate management network. The iDRAC is not designed nor intended to be placed on, nor connected directly to the Internet. Doing so could expose the connected system to security and other risks for which Dell EMC is not responsible.
  • Dell EMC recommends using the Dedicated Gigabit Ethernet port available on rack and tower servers to connect the iDRAC to a separate management network.
  • Along with locating iDRAC on a separate management network, users should isolate the management subnet/vLAN with technologies such as firewalls, and limit access to the subnet/vLAN to authorized server administrators.
  • Dell EMC recommends using 256-bit encryption strength as well as TLS 1.2 or higher. For tighter control, additional ciphers may be removed via "Cipher Select" – see the iDRAC User Guide for more details. 
  • Dell EMC recommends additional settings such as IP range filtering and System Lockdown Mode. 
  • Dell EMC recommends using additional security authentication options such as Microsoft Active Directory or LDAP.
  • Dell EMC recommends keeping iDRAC firmware up to date.

Customers can download software, including the latest release of iDRAC firmware, from the Dell Support site.
https://www.dell.com/support/home/
Customers can find the iDRAC documentation from the Dell EMC Support site.
www.dell.com/idracmanuals

Remerciements

CVE-2020-5366: Dell EMC would like to thank Georgy Kiguradze and Mark Ermolov from Positive Technologies

Informations connexes


Propriétés de l’article


Produit concerné

iDRAC9 - 3.0x Series, iDRAC9 - 3.1x Series, iDRAC9 - 3.2x Series, iDRAC9 - 3.3x Series, iDRAC9 - 3.4x Series, iDRAC9 - 4.xx Series, Product Security Information

Dernière date de publication

10 nov. 2021

Version

5

Type d’article

Dell Security Advisory