AppSync: Application Mapping failed while finding VPLEX virtual volumes
Summary:
AppSync isunable get the virtual volumes information with wwn: from VPLEX due to VPLEX management console issues.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
AppSync unable get the virtual volume information with wwn:<wwn_id> from VPLEX cluster due to VPLEX management console issues.
AppSync command failed: https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
The primary error found in the Server Log is:
Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n"
Details surrounding this error are found in the Server Log as seen here:
<date> 10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date> 10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date> 10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: { "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: { "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date> 10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id> in cluster:cluster-1 error:{ "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id> in cluster:cluster-1 error:{ "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date> 10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date> 10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
Cause
This issue is related to the VPLEX management console which is rejecting valid commands passed from AppSync through REST API. This is a known issue in VPLEX.
The reason for the NaN problem is currently believed to be CST JNI native code not being thread-safe and corrupting the FPU registers and interfering with other java threads that need to use the FPU (such as for double numbers).
The reason for the NaN problem is currently believed to be CST JNI native code not being thread-safe and corrupting the FPU registers and interfering with other java threads that need to use the FPU (such as for double numbers).
Resolution
Permanent Resolution:
This issue is fixed in VPLEX GeoSynchrony code version 6.0 Service Pack 1 Patch 4 and later.
Workaround:
- Restart VPLEX management console.
- Re-run the AppSync service plan.
For more details on how to restart the VPLEX Management Console service refer to KB article 000167777: ViPR Controller : Creation of a VPLEX distributed lun fails with Status 524: Infinite or NaN
Additional Information
Affected Products
AppSyncProducts
AppSync, VPLEX SeriesArticle Properties
Article Number: 000057099
Article Type: Solution
Last Modified: 09 Sept 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.