AppSync: Falha no mapeamento de aplicativos ao localizar volumes virtuais do VPLEX

Oversigt: O AppSync não consegue obter as informações de volumes virtuais com wwn: do VPLEX devido a problemas no console de gerenciamento do VPLEX.

Denne artikel gælder for Denne artikel gælder ikke for Denne artikel er ikke knyttet til et bestemt produkt. Det er ikke alle produktversioner, der er identificeret i denne artikel.

Symptomer

O AppSync não consegue obter as informações de volume virtual com wwn:<wwn_id> do cluster do VPLEX devido a problemas no console de gerenciamento do VPLEX.
Falha no comando do AppSync:https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
 
O principal erro encontrado no log do servidor é:
 

Falha ao tentar atualizar as propriedades "storage-views" em\n Exportar.\ncausa:        Infinito ou NaN\n"
 

Os detalhes relacionados a esse erro são encontrados no log do servidor, conforme visto aqui: 
 

<date>  10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date>  10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date>  10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date>  10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: {    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date>  10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date>  10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id>  in cluster:cluster-1 error:{    "response": {        "context": null,        "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ",        "exception": "export        Evaluation of <<export storage-view find -c\nstorage-view  /clusters/cluster-1 -v\nfind:         VPD83T3:<wwn_id> >> failed.\ncause:        Command execution failed.\ncause:        com.emc.vplex.smsv2.business.BusinessException: Failure\n              attempting to refresh properties 'storage-views' on Export.\ncause:        Failure attempting to refresh properties 'storage-views' on\n              Export.\ncause:        Infinite or NaN\n",        "custom-data": null    }}
<date>  10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date>  10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)



Årsag

Esse problema está relacionado ao console de gerenciamento do VPLEX, que está rejeitando comandos válidos passados do AppSync por meio da API REST. Esse é um problema conhecido no VPLEX.

A razão para o problema NaN atualmente acredita-se ser o código nativo JNI CST não ser thread-safe e corromper os registros FPU e interferir com outros threads java que precisam usar o FPU (como para números duplos).

Løsning

Resolução permanente:
Esse problema foi corrigido no VPLEX GeoSynchrony Code versão 6.0 Service Pack 1 Patch 4 e posterior.

Solução alternativa:

  1. Reinicie o console de gerenciamento do VPLEX.
  2. Execute novamente o plano de serviço do AppSync.

Para obter mais detalhes sobre como reiniciar o serviço VPLEX Management Console, consulte o artigo da base de conhecimento 000167777: Controlador ViPR : A criação de uma LUN distribuída do VPLEX falha com o status 524: Infinito ou NaN 


Flere oplysninger


 
 

Berørte produkter

AppSync

Produkter

AppSync, VPLEX Series
Artikelegenskaber
Artikelnummer: 000057099
Artikeltype: Solution
Senest ændret: 09 sep. 2025
Version:  4
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices