AppSync:尋找 VPLEX 虛擬磁碟區時,應用程式對應失敗
Oversigt:
AppSync 無法取得 WWN 的虛擬磁碟區資訊: 中,因為 VPLEX 管理主控台問題。
Denne artikel gælder for
Denne artikel gælder ikke for
Denne artikel er ikke knyttet til et bestemt produkt.
Det er ikke alle produktversioner, der er identificeret i denne artikel.
Symptomer
由於 VPLEX 管理主控台問題,AppSync 無法從 VPLEX 叢集取得 wwn:<wwn_id> 的虛擬磁碟區資訊。
AppSync 命令失敗:https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
在伺服器記錄中找到的主要錯誤為:
嘗試重新整理屬性「儲存檢視」失敗\n 匯出。\n原因: 無限或 NaN\n”
在伺服器日誌中找到有關此錯誤的詳細資訊,如下所示:
<date> 10:07:20.697 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: executing POST: POST https://xxx.xx.xxx.xxx:443/vplex/export+storage-view+find HTTP/1.1
<date> 10:07:20.822 INFO [Thread-404] [com.emc.archway.restclient.RESTClient] [xxxx] [] executeRequest: Response Status Line: HTTP/1.1 541
<date> 10:07:20.822 ERROR [Thread-404] [com.emc.archway.restclient.RESTClientRequest] [xxxx] [] Response is
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] Exception Occurred: RESTClientUnexpectedResponseCodeException, Message: { "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXClient] [xxxx] [] +++The following stack trace is abbreviated.+++
<date> 10:07:20.822 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] Exception Occurred: VPLEXRequestFailedException, Message: { "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXClient.sendSingleVplexRequest(VPLEXClient.java:206) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.executeCLICommand(VPLEXServiceBean.java:1161) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getStorageViewsInfosContainingWwn(VPLEXServiceBean.java:1418) [top 3 frames]
<date> 10:07:20.869 ERROR [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] com.emc.archway.service.vplex.VPLEXServiceBean.getVirtualVolumeIdFromWwn(VPLEXServiceBean.java:914)
<date> 10:07:21.088 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id> in cluster:cluster-1 error:{ "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:21.635 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.vplex.VPLEXServiceBean] [xxxx] [] VPLEXRequestFailedException while finding virtual volume with wwn:<wwn_id> in cluster:cluster-1 error:{ "response": { "context": null, "message": "export storage-view find -c /clusters/cluster-1 -v VPD83T3:<wwn_id> ", "exception": "export Evaluation of <<export storage-view find -c\nstorage-view /clusters/cluster-1 -v\nfind: VPD83T3:<wwn_id> >> failed.\ncause: Command execution failed.\ncause: com.emc.vplex.smsv2.business.BusinessException: Failure\n attempting to refresh properties 'storage-views' on Export.\ncause: Failure attempting to refresh properties 'storage-views' on\n Export.\ncause: Infinite or NaN\n", "custom-data": null }}
<date> 10:07:21.807 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [VNX_000072]: 172.xx.xx.xx\E:\ were mapped to array CKM00xxxx. If the array is a VNX, XtremIO, VPLEX Cluster, VNXe or Unity array, register CKM00xxxxxx. If the array is a VMAX array, register EMC SMI-S Provider managing the VMAX Array.(METADATA: TYPE-INFO, TIME-2017-06-13 10:07:21.807+0100NATIVETIME-2017-06-13 10:07:21.807+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date> 10:07:21.872 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [GENL_000044]: The following application items could not be mapped to any configured storage system: xxxx-SQL-01:ReportServerTempDB.Register the required storage system in AppSync.(METADATA: TYPE-WARNING, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
<date> 10:07:21.888 INFO [Thread-691 (HornetQ-client-global-threads-739147480)] [com.emc.archway.service.eventservice.EventServiceBean] [xxxx] [] EVENT [SPP_000037]: Cannot determine the storage type where application xxxx-SQL-01:ReportServerTempDB resides. Verify if the application is located on a supported EMC storage that has been added to AppSync.(METADATA: TYPE-ERROR, TIME-2017-06-13 10:07:21.872+0100NATIVETIME-2017-06-13 10:07:21.872+0100, HOST-xxxx, PHASE-Application mapping, THREAD=Thread-691 (HornetQ-client-global-threads-739147480), USER-j.leslie, CATEGORY-GENERIC, SESSIONID-1yZV80s43ZbQGSyjn4RQ6zxO6fwKc1Y2UJD-d8aG)
Årsag
此問題與 VPLEX 管理主控台拒絕透過 REST API 從 AppSync 傳遞的有效命令有關。這是 VPLEX 中的已知問題。
目前認為 NaN 問題的原因在於 CST JNI 本機代碼不是線程安全的,並且損壞了 FPU 寄存器並干擾了需要使用 FPU 的其他 Java 線程(例如雙精度數位)。
目前認為 NaN 問題的原因在於 CST JNI 本機代碼不是線程安全的,並且損壞了 FPU 寄存器並干擾了需要使用 FPU 的其他 Java 線程(例如雙精度數位)。
Løsning
永久解決方案:
此問題已在 VPLEX GeoSynchrony 程式碼版本 6.0 Service Pack 1 修補程式 4 及更新版本中修正。
因應措施:
- 重新啟動 VPLEX 管理主控台。
- 重新執行 AppSync 服務計劃。
如需有關如何重新啟動 VPLEX 管理主控台服務的更多詳細資訊,請參閱知識文章 000167777:ViPR 控制器:建立 VPLEX 分散式 LUN 失敗,顯示狀態 524:無限或 NaN
Flere oplysninger
Berørte produkter
AppSyncProdukter
AppSync, VPLEX SeriesArtikelegenskaber
Artikelnummer: 000057099
Artikeltype: Solution
Senest ændret: 09 sep. 2025
Version: 4
Find svar på dine spørgsmål fra andre Dell-brugere
Supportservices
Kontrollér, om din enhed er dækket af supportservices.